Gas Valve Coils - Amana LG4219*2 Service Manual

Home laundry dryers
Table of Contents

Advertisement

a W A R N I N G
To reduce the risk of electric shock, fire, explosion, serious injury or death:
•Disconnect electric power to the dryer before servicing.
•Close gas shut-off valve to gas dryer before servicing.
•Never start the dryer with any guards/panels removed.
•Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.

51. GAS VALVE COILS

a W A R N I N G
To reduce the risk of fire, explosion and
electric shock, close the valve in the
gas supply line to the gas dryer and
disconnect the electrical power unless
gas or power supplies are required to
perform test procedure.
a. While supporting the lower access panel,
remove two screws from bottom edge of lower
access panel, Figure 51.
b. Gently lower the access panel to disengage
guide lugs from bottom edge of front panel.
c. Close gas shut-off valve, Figure 48.
d. Remove disconnect blocks from gas valve
coils.
RS3200001 (502992R3)
Rev. 3
Figure 52
e. Set test meter to read OHMS and put meter
probes to terminals as in Figure 52, and the
chart below.
COIL TOLERANCE READINGS
Holding Coil
Terminals 1 & 2
Booster Coil
Terminals 1 & 3
Secondary Coil
Terminals 4 & 5
NOTE: If meter registers any other readings than
those listed above, the respective coil(s) should
be replaced.
54
W001
60 Hertz
1365 ± 25
Ohms
560 ± 25
Ohms
1220 ± 50
Ohms