a W A R N I N G
To reduce the risk of electric shock, fire, explosion, serious injury or death:
•Disconnect electric power to the dryer before servicing.
•Close gas shut-off valve to gas dryer before servicing.
•Never start the dryer with any guards/panels removed.
•Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
a W A R N I N G
To reduce the risk of electric shock, fire, explosion, serious injury or death:
•Disconnect electric power to the dryer before servicing.
•Close gas shut-off valve to gas dryer before servicing.
•Never start the dryer with any guards/panels removed.
•Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
IMPORTANT: When reference to direction (right or left) is made in this manual, it is from the operator' s
position facing the front of the dryer.

5. CONTROL HOOD ASSEMBLY

(Figures 5, 6, 7 and 8)
a. Remove three screws holding control hood
assembly to control hood rear panel.
b. Rotate assembly forward to access inner
wiring.
c. Disconnect wiring from inner components and
carefully remove components from control
hood assembly.
NOTE: Refer to appropriate wiring diagram when
rewiring component parts.
d. Rotate control hood assembly forward and lift
to free assembly from hold-down clips.
6. FLUORESCENT LIGHT ASSEMBLY (Models
containing fluorescent light only)
(Figures 6 and 7)
a. Remove three screws holding top cover to
control mounting plate. Rotate top cover
forward to release front edge of top cover
from top edge of diffuser, Figures 5, 6, 7 and
8.
b. Disconnect two wires from rocker switch
(located in diffuser).
c. Disconnect wires at disconnect blocks located
in control mounting plate.
d. Remove two screws holding fluorescent light
to control mounting plate.
e. Lift fluorescent light out of control mounting
plate.
SECTION II
Service
Procedures

7. CONTROL HOOD END CAPS

(Figures 5, 6, 7 and 8)
a. Remove three screws holding control hood
assembly to control hood rear panel.
b. Rotate assembly forward to access inner
wiring.
c. Disconnect wiring from inner components and
carefully remove components from control
hood assembly.
NOTE: Refer to appropriate wiring diagram when
rewiring component parts.
d. Remove two screws holding end cap to end
of mounting plate.
e. Carefully pry end cap from control mounting
plate and control panel.
NOTE: To re-assemble reverse the steps.