a W A R N I N G
To reduce the risk of electric shock, fire, explosion, serious injury or death:
•Disconnect electric power to the dryer before servicing.
•Close gas shut-off valve to gas dryer before servicing.
•Never start the dryer with any guards/panels removed.
•Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
Install Three Wire Plus Ground Power Cord
e. Route the end of the three wire plus gound
(earth) power cord through the strain relief.
DO NOT tighten the strain relief screws at this
time.
f. Insert the end of the power cord and strain
relief through the hole in the rear of dryer
cabinet, Figure 58. Install the strain relief nut
from the inside of the cabinet and tighten
firmly.
g. Attach the ground wire (from the three wire
plus gound [earth] power cord) to the terminal
block mounting bracket using the hex head
screw removed in Step d. Tighten the screw
firmly.
h. Using the three wire-binding (10-32x3/8")
screws from the accessories envelope
(located inside the cylinder, unless the screws
were previously removed in Step b), attach
the power cord wires to the terminal block
terminals as follows:
(1) Red to Red
(2) Black to Black
(3) White to White (see NOTE below)
NOTE: When installing the white to white wire,
loop the free eyelet end of the ground wire (from
Step d) and place it together with the white wire.
Attach both wires to the neutral (center) terminal
on the terminal block, Figure 58.
IMPORTANT: Failure to tighten the screws firmly
on the terminal block may result in terminal
block failure.
i. Tighten the two strain relief screws to secure
the power cord.
j. Recheck all screws to be sure they are tight.
k. Reinstall the access plate and screw to the
rear of the dryer cabinet.