e Monitor select buttons
When multiple monitors are connected by the network
connection, one particular monitor, monitor group or all
monitors are selected by setting the MONITOR ID No.,
GROUP ID No. or ALL.
SINGLE
SINGLE button: Single
connection mode is
selected.
GROUP button: Group
connection mode is selected.
f MANUAL adjustment buttons and knobs
Each press of one of these buttons turns the button's green
LED on or off. When the corresponding button is on (lit),
it is possible to manually adjust the contrast, brightness,
chroma and phase by turning the corresponding knobs. The
PHASE knob is also used to enter the setting values with
the menus. It is possible to set the preset value for each
adjusting item with the PICTURE ADJ menu.
CONTRAST
MANUAL
BRIGHT
MANUAL
MANUAL
CHROMA
MANUAL
PHASE
For information about the PICTURE ADJ menu, see "
Picture Adjustment – PICTURE ADJ Menu" on page 28.
Notes
• The signal phase cannot be adjusted when using the
SECAM, PAL, PAL-M, analog component or SDI
(component serial digital or composite PAL) format.
• The phase and chroma cannot be adjusted when using
RGB signals.
12
Location and Function of Parts
REMOTE
ALL
GROUP
ALL button: All connection
mode is selected.
CONTRAST button
and knob
BRIGHT button
and knob
CHROMA button
and knob
PHASE button
and knob
g Menu operation buttons
UP
MENU
DOWN
ENTER
For more information about menu operation, see "Basic
Menu Operations" on page 22.
h OPERATE lamp
Lights when the monitor is put into operation mode from
standby mode (see 9 STANDBY lamp) by pressing the
I/1 switch.
Note
When the STANDBY lamp is blinking, the monitor cannot
be put into operation mode (internal data initialization is
taking place). Wait until the STANDBY lamp is steadily
lit.
i STANDBY lamp
Lights when the monitor is in standby mode. The monitor
will be in standby mode under the following conditions:
• The MAIN POWER switch (on the rear panel) is turned
on (the STANDBY lamp will blink for a few moments
after the switch is turned on, then will light).
• The monitor is changed from operation mode to standby
mode by external control.
j OVER LOAD lamp
Lights to warn of CRT overload.
When the OVER LOAD lamp is lit, use the unit with the
contrast or brightness reduced.
k Monitor select lamps and window
When multiple monitors are connected by the network
connection, one particular monitor, monitor group or all
monitors are selected by setting the MONITOR ID No.,
[A]
GROUP ID No. or ALL.
SINGLE
GROUP
MENU button: Press to display the monitor
menus.
UP/DOWN buttons: Press to select the
items and setting values.
ENTER button: Press to confirm the items
and values entered (Ent button on the
numeric keypad has the same function).
Display window: Selected ID
No. or ALL is displayed. The
display blinks until the remote
connection is completed.
ALL
Lamps: The lamp
corresponding with the pressed
button blinks during setting or
lights after confirming.