5-15 ELECTRICAL SYSTEM
③ Pouring in battery electrolyte
When insert the nozzles of the electrolyte container
into the battery' s electrolyte filler holes, holding the
container firmly so that it cloes not fall.
Take precaution not to allow any of the fluid to spill.
CAUTION
In no case pouring into if put in slopely the
electrolyte container.
④ Confirm of pour
Make sure that air bubbles are coming up each
electrolyte container, and leave in this position for
about more than 20 minutes.
CAUTION
If no air bubbles are coming up from afiller port,
tap the botton of the two or three times.
Cap
Air bubble
Seal