REGULATOR / RECTIFIER
Using the pocket tester (× 1 Ϊ range), measure the
resistance between the lead wires in the following
table.
If the resistance checked is incorrect, replace the
regulator / rectifier.
Pocket tester : 09900-25002
1
1
-
2
7~8
3
7~8
4
7~8
5
35~55
Unit : Ϊ
� Probe of tester
2
3
4
OFF
OFF
OFF
-
OFF
OFF
OFF
-
OFF
OFF
OFF
-
7~8
7~8
7~8
5
OFF
OFF
OFF
OFF
-
ELECTRICAL SYSTEM 5-8
①
②
③
⑤
④