b) less than 4 feet below or horizontally from, or one foot above, any door, window or gravity air inlet into any
building;
c) less than two feet from an adjacent building and not less than 7 feet above grade when located adjacent to a
public walkway. Mobile home installations must use a spark arrester. Other restrictions may apply, such as the
need to maintain a minimum distance to a gas meter. See NFPA 211.
b) b) b) b) Vertically with new chimney system
Vertically with new chimney system
Vertically with new chimney system
Vertically with new chimney system
(Refer to Figure 13)
NOTE: Follow Vent chimney manufacturer's instructions.
NOTE:
NOTE:
NOTE:
OPTION: To achieve a centered vertical installation, a 45º elbow and a clean-out tee can be used to offset the pipe from the
OPTION:
OPTION:
OPTION:
exhaust outlet to the rear center of the stove.
OPTION:
OPTION:
OPTION:
OPTION: Install Vent elbow in place of clean-out tee. Locate stove. Drop plumb bob to center of tee outlet, mark point on
ceiling. Install ceiling support and Vent pipe per Vent manufacturer's instructions.
1.
Always maintain 3" clearance from combustible materials. When passing through additional floors or ceilings,
always install firestop spacer.
2.
After lining up for hole in roof, cut either a round or square hole in roof, always 3" larger all the way around pipe.
Install upper edge and sides of flashing under roofing materials, nail to the roof along upper edge. Do not nail lower
edge. Seal nail heads with flexible waterproof sealant.
Apply flexible, waterproof sealant where the storm collar meets the vent. Slide storm collar down until it sits on the
3.
flashing. Seal and install cap. Mobile home installations must use a spark arrester.
CONSULT THE VENT MANUFACTURER'S INSTRUCTIONS.
CONSULT THE VENT MANUFACTURER'S INSTRUCTIONS
CONSULT THE VENT MANUFACTURER'S INSTRUCTIONS
CONSULT THE VENT MANUFACTURER'S INSTRUCTIONS
FIGURE 12
Venting through wall
Basement installation