Main Components; Introduction To The E-Smart Controls Platform - REMEHA Quinta Ace 30 Installation And User Manual

High-efficiency wall-hung gas boiler
Hide thumbs Also See for Quinta Ace 30:
Table of Contents

Advertisement

3 Description of the product
3.2

Main components

Fig.1
Main components
1
2
3
4
5
6
7
8
9
10
11
12
1 Casing/air box
2 Heat exchanger (CH)
3 Interior light
4 Type plate
5 Flow sensor
6 Ionisation/ignition electrode
7 Mixing tube
8 Non-return valve
9 Combined gas valve unit
10 Return sensor
11 Air intake silencer
12 Instrument box
13 Siphon
3.3

Introduction to the e-Smart controls platform

Fig.2
Generic example
SCB
GTW
MK
10
21
20
19
18
17
16
15
14
13
The Quinta Ace boiler is equipped with the e-Smart controls platform. This
is a modular system, and offers compatibility and connectivity between all
products that make use of the same platform.
R-Bus
CU
CB
L-Bus
S-Bus
GTW
2
14 Expansion box for the control PCBs
(= accessory)
15 Automatic air vent
16 Hydraulic pressure sensor
17 Fan
18 Supply line
19 Flue gas measuring point
20 Flue gas discharge
21 Air supply
Heating circuit flow
Heating circuit return
RU
AD-4000070-03
C
B
A
AD-3001366-02
7684359 - v.11 - 13122021

Hide quick links: