Setting Up The X-Y Origin - SunStar SPS/ D-B1254 Series User Manual

Sps/d-b1254, sps/d-b1263 series direct drive, electronically controlled decorative pattern tacking machine (mechanical part)
Table of Contents

Advertisement

15) Setting Up the X-Y Origin

A. How to set up X-axis origin
Separate a bed cover (left).
Move the center of work clamp foot to be placed on the center of X-axis.
As seen in the figure, unfasten the bolts of X-sensor plate and let the end of X-sensor plate locate on the center
of sensor, then fasten the bolts with screw-driver.
B. How to set up the O-point of the Y-axis
Separate the bed cover (on the right).
Adjust the distance
Move the feed bracket to position the center of the upper feed plate at the center of the Y-axis. You shall
keep the distance
After adjusting the end of Y-sensor plate to correct with the sensor center by unfastening the joint screw in the
Y-sensor sensing plate as shown in the Figure, fasten the joint screw using a spanner.
between the Y-transfer arm
to 24mm.
Screw
X-Sensor Plate
Sensor
and the bed surface
to 24mm.
Screw
[ Fig. 60 ]
Sensor
Y-Sensor
Plate
[ Fig. 61 ]
35