Test 7 Gas Valve Test - Gas Type - Kenmore 796.8051 Service Manual

Electric & gas dryer
Hide thumbs Also See for 796.8051:
Table of Contents

Advertisement

Test 7
GAS Valve test - Gas Type
BL3
YL2
The flame sensor is closed and the ignitor is OK.
• Perform the functional test above.
• Check all wiring and connectors to gas valve components.
• Check gas supply.
Disconnect the BL3 Connector
from the main PCB and measure
the resistance between BL3-1
(RD) and BL3-2 (PK). Is the
resistance 1.5k-2.5k Ω ?
YES
Measure the resistance between
BL3-1 (RD) and BL3-3 (WH). Is
the resistance 1.5k-2.5k Ω ?
YES
Disconnect the YL3 connector
from the main PCB. Measure
the resistance between YL3-1
(GY) and YL3-3 (BL). Is the
resistance <1 Ω ?
YES
Measure the resistance between
YL3-3 (BL) and the blue wire on
the black tab relay. Is the
resistance 100-800 Ω ?
YES
25
• Check wiring and connectors
to gas valve.
• See gas valve component
NO
test.
• Check wiring and connectors
to gas valve.
• See gas valve component
test.
NO
• Check wiring and connectors
to flame sensor.
• See flame sensor component
NO
test.
• Check wiring and connectors
to the ignitor
• See ignitor component test
NO