Xantrex XTR 6-110 Operating Manual page 83

Xtr 850 watt series programmable dc power supply
Hide thumbs Also See for XTR 6-110:
Table of Contents

Advertisement

Table 3-9 Power Supply Default Settings
Parameter
Foldback trigger
Foldback delay
Current Share Mode
Alarm Output Latches
Alarms Mask
Interlock
Voltage Analog Programming
Voltage APG Scale
Current Analog Programming
Current APG Scale
To reset the power supply:
1. Turn the front panel power switch to the Off position.
2. Allow the unit to power down.
3. When the fans are off and the front panel displays are not illuminated,
turn the power switch to the On position.
4. Press and hold the OUTPUT ON/OFF and AUX ON/OFF buttons.
The front panel should display P5U S rS.
5. When the display reads P5u Clr, release the OUTPUT ON/OFF and
AUX ON/OFF buttons. After 1 second the model number will appear
on the display for 1 second.
The power supply has been reset.
M370046-01
Resetting the Power Supply
Setting
None
0.5 s
MASTer
263 (0 × 107, all latches enabled)
2047 (0 × 7FF, all enabled)
Disabled
Off
10 V
Off
10 V
3