Xantrex XTR 6-110 Operating Manual page 58

Xtr 850 watt series programmable dc power supply
Hide thumbs Also See for XTR 6-110:
Table of Contents

Advertisement

Local Operation
Important:
output voltage up to 105% over the model-rated maximum value. The power
supply will operate within these extended ranges, but full performance to
specification is not guaranteed.
The SCPI command (s) for these instructions are:
Quick Tip
Remote operation
[[:]SOURce[<channel>]]:VOLTage[:LEVEl][:IMMediate]
uses these SCPI
[:AMPLitude]
commands. See
page 5–1.
Important:
are limited by the Over Voltage Protection and Under Voltage Protection settings.
To set the current set point (I
1. Turn the mode control knob to the CUR position or press the Rotary
2. Set the desired current value using the Rotary knob/Enter button.
3. Press the Rotary knob/Enter button to transition to Fine Adjust mode.
4. Set the desired current value using the Rotary knob/Enter button.
5. Once the desired value has been set, press the Rotary knob/Enter
Important:
current can be set up to 105% over the model-rated maximum values. The power
supply will operate within these extended ranges, but full performance to
specification is not guaranteed.
The SCPI command (s) for these instructions are:
[[:]SOURce[<channel>]]:CURRent[:LEVEl][:IMMediate]
[:AMPLitude]
3-14
The control circuits have been designed to allow you to set the
The maximum and minimum setting values of the output voltage
knob/Enter button if the mode control knob is already at the CUR
position.
The voltage set point is blinking in the output voltage display. The
output current will be displayed in the output current display.
The set point blinks faster to indicate fine adjust tracking mode.
button to commit the setting.
The control circuits have been designed so that output
):
SET
M370046-01

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xtr 850 watt seriesXtr 8-100Xtr 12-70Xtr 20-42Xtr 33-25Xtr 40-21 ... Show all