Local Operation
To access the tracking mode for entering voltage and current:
1. Select the VOL or CUR position on the mode control knob.
2. Use the Rotary knob/Enter button to adjust the set point.
3. Press the Rotary knob/Enter button to enter fine adjust tracking mode.
4. Use the Rotary knob/Enter Button to fine tune the set point.
5. Once the set point has been selected, press the Rotary knob/Enter
To access the select and set entry mode for the voltage and current set
points:
1. Select VOL or CUR position on the mode control knob.
2. Press the Rotary knob/Enter button twice to scroll past the coarse and
3. If a change is made accidentally in tracking mode, select and set
4. Select the desired value for this set point and then set the value using
3-6
If the set point is blinking, the unit is in coarse tracking mode.
•
When the VOL mode is selected, the voltage set point will blink
in the output voltage display.
•
When the CUR mode is selected, the current set point will blink
in the output current display.
The adjustments you make to the set point affect the opposing output
value (voltage when in CUR mode or current when in VOL), which
will update in the non-blinking display.
The set point blinks faster when the unit is in fine adjust tracking
mode.
Button to exit tracking mode and return to normal display mode.
fine tracking modes without making any adjustment to the value.
Coarse select and set mode has been selected.
mode will not be available and you'll need to start again at Step 1.
the Rotary knob/Enter button.
M370046-01