General Hardware Problems - HP ProLiant DL100 Series User Manual

Proliant dl100 series server
Hide thumbs Also See for ProLiant DL100 Series:
Table of Contents

Advertisement

General hardware problems

Problems with new hardware (on page 71)
Unknown problem (on page 70)
Third-party device problems (on page 72)
Testing the device (on page 72)
Problems with new hardware
Action:
Refer to the server documentation to be sure the hardware being installed is a supported option on
1.
the server. Remove unsupported hardware.
Refer to the release notes included with the hardware to be sure the problem is not caused by a last
2.
minute change to the hardware release. If no documentation is available, refer to the HP support
website (http://www.hp.com/support).
Be sure the new hardware is installed properly. Refer to the device, server, and operating system
3.
documentation to be sure all requirements are met.
Common problems include:
Incomplete population of a memory bank
o
Installation of a processor without a corresponding PPM
o
Installation of a SCSI device without termination or without proper ID settings
o
Setting of an IDE device to Primary/Secondary when the other device is set to CS
o
Connection of the data cable, but not the power cable, of a new device
o
Be sure no memory, I/O, or interrupt conflicts exist.
4.
Be sure no loose connections (on page 54) exist.
5.
Be sure all cables are connected to the correct locations and are the correct lengths. For more
6.
information, refer to the server documentation.
Be sure other components were not unseated accidentally during the installation of the new
7.
hardware component.
Be sure all necessary software updates, such as device drivers, ROM updates, and patches, are
8.
installed and current. For example, if you are using a Smart Array controller, you need the latest
Smart Array Controller device driver.
Be sure all device drivers are the correct ones for the hardware. Uninstall any incorrect drivers
9.
before installing the correct drivers.
Press the F10 key to run the BIOS Setup Utility after boards or other options are installed or replaced
10.
to be sure all system components recognize the changes. If you do not run the utility, you may
receive a POST error message indicating a configuration error. After you check the settings in the
BIOS setup menu, press the F10 key to save and exit the utility, and then restart the server.
Be sure all switch settings are set correctly. For additional information about required switch settings,
11.
refer to the labels located on the inside of the server access panel or the server documentation.
Be sure all boards are properly installed in the server.
12.
Run HP Insight Diagnostics (on page 51) to see if it recognizes and tests the device.
13.
Uninstall the new hardware.
14.
Troubleshooting 71