General Hardware Problems - HP ML110 G2 User Manual

Proliant 100 series
Hide thumbs Also See for ML110 G2:
Table of Contents

Advertisement

Be sure the UPS power switch is in the On position. See the UPS documentation for the location of
2.
the switch.
Be sure the UPS software is updated to the latest version. Use the Power Management software
3.
located on the Power Management CD.
Be sure the power cord is the correct type for the UPS and the country in which the server is located.
4.
See the UPS reference guide for specifications.
Be sure the line cord is connected.
5.
Be sure each circuit breaker is in the On position, or replace the fuse if needed. If this occurs
6.
repeatedly, contact an authorized service provider.
Check the UPS LEDs to be sure a battery or site wiring problem has not occurred. See the UPS
7.
documentation.
If the UPS sleep mode is initiated, disable sleep mode for proper operation. The UPS sleep mode can
8.
be turned off through the configuration mode on the front panel.
Change the battery to be sure damage was not caused by excessive heat, particularly if a recent air
9.
conditioning outage has occurred.
NOTE: The optimal operating temperature for UPS batteries is 25°C (77°F). For approximately every 8°C to
10°C (16°F to 18°F) average increase in ambient temperature above the optimal temperature, battery life is
reduced by 50 percent.
Low battery warning is displayed
Action:
Plug the UPS into an AC grounded outlet for at least 24 hours to charge the batteries, and then test
1.
the batteries. Replace the batteries if necessary.
Be sure the alarm is set appropriately by changing the amount of time given before a low battery
2.
warning. Refer to the UPS documentation for instructions.
One or more LEDs on the UPS is red
Action: Refer to the UPS documentation for instructions regarding the specific LED to determine the cause
of the error.

General hardware problems

Problems with new hardware
Action:
Refer to the server documentation to be sure the hardware being installed is a supported option on
1.
the server. Remove unsupported hardware.
Refer to the release notes included with the hardware to be sure the problem is not caused by a last
2.
minute change to the hardware release. If no documentation is available, refer to the HP support
website (http://www.hp.com/support).
Be sure the new hardware is installed properly. Refer to the device, server, and operating system
3.
documentation to be sure all requirements are met.
Common problems include:
Incomplete population of a memory bank
Installation of a processor without a corresponding PPM
Installation of a SCSI device without termination or without proper ID settings
Setting of an IDE device to Primary/Secondary when the other device is set to CS
Troubleshooting 55