Hp Trusted Platform Module Option; Installing The Trusted Platform Module Board - HP ProLiant DL100 Series User Manual

Proliant dl100 series server
Hide thumbs Also See for ProLiant DL100 Series:
Table of Contents

Advertisement

Install the access panel.
11.
Install the server into the rack.
12.
Power up the server (on page 15).
13.

HP Trusted Platform Module option

Use these instructions to install and enable a TPM on a supported server. This procedure includes three
sections:
Installing the Trusted Platform Module board (on page 42).
1.
Retaining the recovery key/password (on page 44).
2.
Enabling the Trusted Platform Module (on page 44).
3.
TPM installation requires the use of drive encryption technology, such as the Microsoft® Windows®
BitLocker™ Drive Encryption feature. For more information on BitLocker™, see the Microsoft website
(http://www.microsoft.com).
CAUTION:
can cause hardware damage or halt data access.
When installing or replacing a TPM, observe the following guidelines:
Do not remove an installed TPM. Once installed, the TPM becomes a permanent part of the system
board.
When installing or replacing hardware, HP service providers cannot enable the TPM or the
encryption technology. For security reasons, only the customer can enable these features.
When returning a system board for service replacement, do not remove the TPM from the system
board. When requested, HP Service provides a TPM with the spare system board.
Any attempt to remove an installed TPM from the system board breaks or disfigures the TPM security
rivet. Upon locating a broken or disfigured rivet on an installed TPM, administrators should consider
the system compromised and take appropriate measures to ensure the integrity of the system data.
When using BitLocker™, always retain the recovery key/password. The recovery key/password is
required to enter Recovery Mode after BitLocker™ detects a possible compromise of system integrity.
HP is not liable for blocked data access caused by improper TPM use. For operating instructions, see
the encryption technology feature documentation provided by the operating system.

Installing the Trusted Platform Module board

WARNING:
equipment, remove the power cord to remove power from the server. The front panel Power
On/Standby button does not completely shut off system power. Portions of the power supply
and some internal circuitry remain active until AC power is removed.
WARNING:
internal system components to cool before touching them.
Power down the server (on page 15).
1.
Remove the server from the rack, if necessary
2.
Always observe the guidelines in this document. Failure to follow these guidelines
To reduce the risk of personal injury, electric shock, or damage to the
To reduce the risk of personal injury from hot surfaces, allow the drives and the
("Remove the server from the
Hardware options installation 42
rack" on page 15).