10. Are there Cycle Time adjustments on the Control Board for different types of fuel?
Answer: There are 4 individual programs on the control board, each
with a different Cycle time.
The Control board has been factory set at the 7.5-second Cycle Time.
When reprogramming the control board, you will see all of the LED
lights flash, as shown in the figure to the right. The LED lights flash in
the following manner:
Program 1 - 7.5 second cycle time. The LED's flash once. This
program is for use with Pellets & Cherry Pits.
Program 2 - 8.5 second cycle time. The LED's flash twice. This
program is for use with Pellets, Cherry Pits, Corn, Wheat, Rye,
Distillers Grain.
Program 3 - 9.5 second cycle time. The LED's flash three times.
This program is for use with Pellets, Cherry Pits, Corn, Wheat, Rye,
Distillers Grain.
Program 4 - 10.5 second cycle time. The LED's flash four times.
This program is for use with Pellets, Cherry Pits, Corn, Wheat, Rye,
Distillers Grain.
11. How do I change to a different Program on the control board?
First the Stove must be turned off and cooled down.
Step 1 - The Thermostat switch must be in the Manual position.
Step 2 – Press and hold both of the Draft Trim High and Low
Buttons.
Step 3 – Press the Auger Feed Button. Release all 3 buttons at the
same time.
Step 4 – Observe the LED light flashing as described in point 10
above.
Changing the Cycle Time will change the BTU Input of the Stove. The
longer the Cycle time the lower the BTU rating.
Lincoln SCR Manual
62
Figure 31
Figure 32