Ashpan. Empty the ash pan when it appears full (approximately twice a week). The
frequency of cleaning the ash pan will depend on the quality and amount of
Corn/Pellets being used. Carefully check to make sure the ash pan door is tightly
closed after each time it has been opened.
2. Revolution Burnpot. Clean Burn Grate holes whenever needed. Clean the burnpot
while it is in the Stove. Remove the pot Side Shields (See Figure 19 on Page 31) and
use a stiff bristle brush to remove any ash build that may be plugging the holes. To
clean the holes in the front of the pot remove the panel below the door and then
remove the Igniter Assembly. Clean the holes in the front of the pot through the
opening behind the Igniter. If the unit is slow in lighting, make sure the hole in
front of the igniter is not plugged.
By tripping the switch lever,
shown in detail in figure 28
below, the burn pot will cycle to
another section. Repeat this until
all 4 sections of the drum have
been cleaned. Check each section
and all holes with a small mirror
to verify they are clean.
If the holes in the pot remain
plugged, remove the Burnpot, (as
shown in Figure 19 on Page 31
& figure 20 on page 32) and use
a small metal object (Nail, Drill
Bit, etc) to clean out plugged
holes.