To The Installer; Installer Safety; Site Preparation; Air Cooled Units - Taylor 161 Operator's Manual

Soft serve freezer
Table of Contents

Advertisement

Section 1
The following information has been included in the
manual as safety and regulatory guidelines. For
complete installation instructions, please see the
Installation Checklist.

Installer Safety

In all areas of the world, equipment should be
installed in accordance with existing local codes.
Please contact your local authorities if you have any
questions.
Care should be taken to ensure that all basic safety
practices are followed during the installation and
servicing activities related to the installation and
service of Taylor equipment.
Only authorized Taylor service personnel
S
should perform installation and repairs on the
equipment.
Authorized service personnel should consult
S
OSHA Standard 29CFRI910.147 or the
applicable code of the local area for the
industry
standards
procedures before beginning any installation
or repairs.
Authorized service personnel must ensure
S
that the proper PPE is available and worn
when required during installation and service.
Authorized service personnel must remove all
S
metal jewelry, rings, and watches before
working on electrical equipment.
The main power supply(s) to the freezer must
be disconnected prior to performing any repairs.
Failure to follow this instruction may result in personal
injury or death from electrical shock or hazardous
moving parts as well as poor performance or damage
to the equipment.
Note: All repairs must be performed by an
authorized Taylor Service Technician.
This unit has many sharp edges that can
cause severe injuries.
Model 161
on
lockout/tagout
1

To the Installer

Site Preparation

Review the area where the unit will be installed before
uncrating the unit. Make sure that all possible hazards
to the user and the equipment have been addressed.
For Indoor Use Only: This unit is designed to operate
indoors, under normal ambient temperatures of
70_-75_F (21_-24_C). The freezer has successfully
performed
in
high
ambient
104_(40_C) at reduced capacities.
This unit must NOT be installed in an area
where a water jet or hose can be used. NEVER use a
water jet or hose to rinse or clean the unit. Failure to
follow this instruction may result in electrocution.
This unit must be installed on a level surface
to avoid the hazard of tipping. Extreme care should be
taken in moving this equipment for any reason. Two or
more persons are required to safely move this unit.
Failure to comply may result in personal injury or
equipment damage.
Uncrate the unit and inspect it for damage. Report any
damage to your Taylor Distributor.
This piece of equipment is made in the USA and has
USA sizes of hardware. All metric conversions are
approximate and vary in size.

Air Cooled Units

DO NOT obstruct air intake and discharge openings:
The Model 161 requires 6" (152 mm) on both sides,
and 0" at the rear. Install the skirt provided on the right
side of the unit. Minimum air clearances must be met
to assure adequate air flow for optimum performance.
temperatures
of
131122
To the Installer