INSTALLATION

SECURE HEATER TO FLOOR

NOTE: Clearance requirements as detailed in "Clearances and Height Requirements" section
of this manual must be met before securing heater in place.
To prevent movement, the heater must be secured to the floor or hearth.
1. Lift off louvers and remove the screen.
2. Remove log set.
3. To remove the grate and base assembly, take out two screws as shown in Figure 11.
4. Lift grate and base assembly out of the firebox.
5. Secure the firebox with two anchoring screws (3/16" x 1Z\v" length) supplied with the
fireplace system. Figure 12
NOTE: If the unit is mounted on carpeting, tile or combustible material without the hearth, a
metal or wooden base covering the entire width and depth of the base must be installed.
Figure 11 -
Remove Grate and Base Assembly
Fp2787
ISDG remove grate
23D8036
33ISDG Vent Free Gas Fireplace System
FP2787
Figure 12 -
Secure Firebox to Floor or Hearth
FP2788
ISDG secure firebox
FP2788