Majestic 360DVS3 Homeowner's Installation And Operating Manual

Multisided top/rear vent convertible direct vent fireplaces

Advertisement

INSTALLER/CONSUMER
SAFETY INFORMATION
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE
IMPORTANT: Read all instructions
and warnings carefully before
starting installation. Failure to follow
these instructions may result in a
possible fire hazard, and will void the
warranty.
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result, causing property
damage, personal injury, or loss of life.
FOR YOUR SAFETY:
• Installation and service must be per-
formed by a qualified installer, service
agency, or
the gas supplier.
• Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
If you smell gas:
1. Open windows
2. Do not touch electrical switches.
3. Do not try to light any appliance.
4. Extinguish any open flame.
5. Do not use any telephone in your
building.
6. Immediately call your gas supplier
from a neighbor's phone.
7. Follow your gas supplier's
instructions.
8. If you cannot reach your gas supplier,
call the fire department.
Multisided Top/Rear Vent
Convertible Direct Vent
Fireplaces:
Homeowner's Installation
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
360DVS2
360DVS3
360DVSL
360DVSR
and Operating Manual
� � �� � � � � �
10006326 6/06 Rev. 1

Advertisement

Table of Contents
loading

Summary of Contents for Majestic 360DVS3

  • Page 1 Multisided Top/Rear Vent Convertible Direct Vent Fireplaces: Homeowner’s Installation and Operating Manual INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. 360DVS2 360DVS3 360DVSL 360DVSR � � �� � � � � � 10006326 6/06 Rev. 1...
  • Page 2: Locating Your Fireplace

    Installation & Operating Instructions This gas appliance should be installed by a qualified installer in accordance with local building codes and current CSA-B149.1 Installation Codes for Gas Burning Appliances and Equipment. If the unit is being installed in a mobile home, the installation should comply with the current CAN/CSA Z 240.4 code.
  • Page 3: Appliance Dimensions

    Rear Vent Configuration Electrical Access Gas Line Access Top Vent Configuration Electrical Access Gas Line Access Fig. 2a Fireplace specifications—360DVS2 Ref. Fireplace Dimensions - 360DVS2 6326 360DVS2 rear vent specs 6326 360DVS2 Appliance Dimensions top vent specs Rear Vent Configuration 38¹⁄₈”...
  • Page 4 Fireplace Dimensions - 360DVS3 / 306DVSL / 360DVSR Rear Vent Configuration Top Vent Configuration Fig. 2b Fireplace specifications—360DVS3/ 360DDVSL/ 360DVSR Ref. 10006326 Electrical Access Gas Line Access 6326 360DVS3 rear vent specs Electrical Access Gas Line Access 6326 360DVS3 top vent...
  • Page 5: Framing Dimensions

    Rear Vent Configuration Top Vent Configuration Fig. 3a Fireplace framing dimensions—360DVS2 Ref. Rear Vent Configuration 24” (610 mm) minus two times finishing material thickness to be even with face of unit. 38⁵⁄₈” (981 mm) Not to be framed until unit is set in place due to 3¹⁄₈”...
  • Page 6 Framing Dimensions - 360DVS3 / 360DVSL / 360DVSR Rear Vent Confiration 360DVSL Top Vent Configuration 360DVSL Fig. 3b Fireplace framing dimensions—360DVS3/ 360DVSL/ 360DVSR Ref. Rear Vent Configuration Model 360DVS3 (See Note 1) 38⁵⁄₈” (981 mm) 40⁵⁄₈” (1032 mm) minus one time (1x) finishing material thickness to be even with face of unit.
  • Page 7: Clearance To Combustibles

    Clearance to Combustibles Appliance Top ...0” (0 mm) to standoff Bottom ... 0” (0 mm) Vent End ... 1/2” (13 mm) to rear panel Nonvent End (DVS2) ... 0” (0 mm) Venting Concentric sections of DV Vent: Top, bottom & sides ... 1” (25 mm) Nonconcentric sections of DV Vent: Side and bottom ...
  • Page 8: Framing And Finishing

    In Canada, please consult provincial and/or local authorities having jurisdiction for installations above 4,500 feet (1,370 m). 360DVS2/ 360DVS3/ 360DVSL/ 360DVSR ANSI Z21.88-2005 / CSA 2.33-2005 When purging the gas lines, the window frame assembly must be removed.
  • Page 9: Electrical Junction Box Connection

    The gas control is equipped with a captured-screw type pressure test point, therefore it is not necessary to pro- vide a 1/8” test point upstream of the control. When using copper or flex connector, use only ap- proved fittings. Always provide a union when using black iron pipe so that the gas line can be easily discon- nected for burner or fan servicing.
  • Page 10: Optional Top Vent Application

    Fig. 8 Alternate switch location. Optional Top Vent Application This appliance is shipped as a rear vent unit. If the installation layout requires the unit to be a top vent con- figuration, the appliance can be converted by following the steps below. When removing and refitting the plates and adapter, be sure the associated gasket is undamaged and refitted as required.
  • Page 11: General Venting

    Electronic Gas Control Valve This appliance may be fitted with a Honeywell ignition module. Installation of the remote ON/OFF starter switch on electronic ignition units (Fig. 12): 1. Thread the wiring through the holes on the side panels of the appliance. Take care not to cut the wire or insulation on metal edges.
  • Page 12: General Venting Information - Termination Location

    General Venting Information - Termination Location VENT TERMINATION CFM145a A = Clearance above grade, veranda, porch, deck, or balcony B = Clearance to window or door that may be opened C = Clearance to permanently closed window D = Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2’...
  • Page 13: Termination Clearances

    Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Combustible 6"(152mm) Noncombustible 2"(50mm) Balcony - with no side wall Combustible & Noncombustible 12"(305mm) Fig. 14 Termination clearances. General Information Assembling Vent Pipes Canadian Installations: Venting system must be installed in accordance with the current CSA-B149.1 installation code.
  • Page 14: How To Use The Vent Graph

    How to Use the Vent Graph The vent chart should be read in conjunction with the following vent installation instructions to determine the relationship of the vertical and horizontal dimensions of the vent system. 1. Determine the height of the center of the horizontal vent pipe exiting through the outer wall.
  • Page 15: Vertical Sidewall Application

    Vent Opening for Combustible Wall 9³⁄₈” (240mm) 10³⁄₈” (265mm) Vent Opening for Noncombustible Wall 7¹⁄₂” (190mm) Fig. 18 Locate vent opening on rear wall. VO584-100 Vent Opening 2/99 djt #8 Screws (2) Firestop CFM135a Fig. 19 Adjustable zero clearance sleeve. STEP 3 Measure the horizontal length requirement for the vent- ing including a 2”...
  • Page 16: Vertical Side Wall Installation

    Horizontal plane means no vertical rise exists on this portion of the vent assembly. • The maximum number of 90˚ elbows per side wall installation is three (3). • If a 90˚ elbow is fitted directly on top of the fireplace flange, the maximum horizontal vent run before the termination or a vertical rise is 36”...
  • Page 17 Vent Opening for Combustible Wall 9³⁄₈” (240mm) 9³⁄₈” (240mm) Vent Opening for Noncombustible Wall 7¹⁄₂” (190mm) Fig. 24 Locate vent opening on rear wall. VO584-100 Vent Opening 2/99 djt #8 Screws (2) Firestop CFM135a Fig. 25 Adjustable zero clearance sleeve. STEP 3 Place fireplace into position.
  • Page 18: Below Grade Installation

    2” (51 mm). Secure termination to the wall with screws provided, and caulk around the wall plate to weather- proof. One alternative to screwing the termination directly to the wallis the use of expanding plugs or an approved exterior construction adhesive. Or, you may attach the termination with screws through the inner body into the 4”...
  • Page 19: Vertical Through-The-Roof Application

    Vertical Through-the-Roof Application This Gas Fireplace has been approved for: • Vertical installations up to 40’ (12 m) in height. Up to a 10’ (3 m) horizontal vent run can be installed within the vent system using a maximum of two 90° elbows.
  • Page 20: Vertical Through-The-Roof Installation

    Vertical Through-the-Roof Installation 1. Locate your fireplace. 2. Plumb to center of the (4”) flue collar from ceiling above and mark position. 3. Cut an opening equal to 9³⁄₈” x 9³⁄₈” (240 x 240mm). 4. Proceed to plumb for additional openings through the roof.
  • Page 21: Twist Lock Venting Components

    584A venting components rear vent term 4/6/99 djt 584B Vent components 584C Starter Kit Vent components 2/25/99 djt 584D 45 degree elbow Vent Components 2/25/99 djt 90 degree elbow 10/20/99 twistlock 2/25/99 djt 584E 10/20/99 twist lock Venting Components Telescope vent 2/25/99 djt 10/20/99 twist lock 584F...
  • Page 22: Glass Information

    fireplace. • The lower end louvre assembly on the 360DVS3/ SL/ SR units is removed in the same manner as the top louvre assemblies. FP1227 Fig.
  • Page 23: Glass Cleaning

    (2) end vertical panels, as shown in Figure 39. 360DVSL and 360DVSR units are each fitted with one end vertical panel and two side vertical panel. The 360DVS3 has only one end vertical panel. Vertical Panels in Place When Shipped FP1446 Fig.
  • Page 24: Flame & Temperature Adjustment

    B123 Fig. 40 360DVS log placement. B121 B122 Fig. 41 360DVS log placement. Lava Rock and Ember Material Placement Your log set contains Ember Material and two types of Lava Rocks. Set these materials in place after the logs have been installed. Ember Material (Pt.
  • Page 25: Flame Characteristics

    Turn counterclockwise to increase flame height Fig. 43 Flame adjustment knob for SIT valve. Flame Characteristics FP390 It is important to periodically perform a visual check FLAME ADJUSTMENT KNOB of the pilot and burner flames. Compare them to the 11/21/96 pictorials illustrated below.
  • Page 26: Cleaning The Standing Pilot Control System

    Burner and Burner Compartment It is important to keep the burner and the burner com- partment clean. At least once per year remove the logs and lava rock/ember material. Vacuum and wipe out the burner compartment. Remove and refit the logs per the instructions in this manual.
  • Page 27 15a/b 34a/b CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. 360DVS Series 10006326 16a/b 4a/b 6326 360DVS parts 3a/b 5a/b 31a/b...
  • Page 28 Fan Speed Control (optional) Fan Speed Control Knob (optional) Electric Cord Remote ON/OFF switch (RN/RP models) Wiring Harness (remote switch) Remote ON/OFF Switch Kit (incls. bracket) Louvre Assembly, side top. 360DVS2 360DVS3 360DVSL 10006350 10006350 10006350 10006315 10006315 10006315 10006316...
  • Page 29 SIT822 Gas Control Valve EP Sensing Electrode (w/ Cable) EN/EP Transformer 24V EN/EP Ignition Module Honeywell EP Wire Harness Honeywell EN/EP 10006326 (Items marked ‘*’ are not shown in the parts illustration) 360DVS2 360DVS3 10000040 10000040 10002411 10002412 52356 52356 57483...
  • Page 30: Limited Lifetime Warranty

    PRODUCT COVERED BY THIS WARRANTY All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic brand gas fireplaces equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner. BASIC WARRANTY CFM Corporation (hereinafter referred to collectively as the Company) warrants that your new Vermont Castings or Majestic Gas Fireplace/ Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions...
  • Page 31: Efficiency Ratings

    Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency (%) 360DVS2RN 62.4 360DVS2RP 62.4 360DVS2EN 62.4 360DVS2EP 62.4 360DVS3RN 62.4 360DVS3RP 62.4 360DVS3EN 62.4 360DVS3EP 62.4 360DVSLRN 62.4 306DVSLRP 62.4 360DVSLEN 62.4 360DVSLEP 62.4 360DVSRRN 62.4 360DVSRRP 62.4 360DVSREN 62.4 360DVSREP 62.4 2695 Meadowvale Blvd.

This manual is also suitable for:

360dvs2360dvsl360dvsr

Table of Contents