Clean face direct vent fireplace insert (48 pages)
Summary of Contents for Majestic 33BDVT
Page 1
Builder Top Vent SION MAY RESULT CAUSING PROPERTY DAMAGE, PER- Direct Vent SONAL INJURY OR LOSS OF LIFE. Models: 33BDVT, 36BDVT FOR YOUR SAFETY 39BDVT, 43BDVT Installation and service must be performed by a qualified installer, service agency or the gas supplier.
BDVT Series Direct Vent GaS Fireplace Installation & Operating Instructions This gas fireplace should be installed by a qualified This appliance may be installed in an aftermarket installer in accordance with local building codes and with permanently located, manufactured home or mobile current CSA-B149.1 Installation codes for Gas Burning home, where not prohibited by local codes.
BDVT Series Direct Vent Gas Fireplace 33BDVT / 36BDVT / 39BDVT / 43BDVT Framing and Finishing Certified To 1. Choose the unit location. ANSI Z21.88-2002 / CSA 2.33-2002 2. Place the unit into position and secure it to the floor Vented Gas Fireplace Heaters with 1¹⁄₂”...
BDVT Series Direct Vent GaS Fireplace Gas Line Installation Remote ON/OFF Switch Installation: When purging gas line, the front window frame assembly must be removed. 1. Thread the wiring through holes on the end panels of appliance. Take care not to cut wire or insulation on metal edges.
BDVT Series Direct Vent Gas Fireplace EB-1 Electrical Box Electronic Gas Control Valve This appliance may be fitted with a Honeywell The fireplace, when installed, must be ignition module. electrically connected and grounded in Installation of the remote on/off switch on elec- accordance with local codes or, in the tronic ignition units.
BDVT Series Direct Vent GaS Fireplace General Venting Your fireplace is approved to be vented either through Do not locate termination hood where excessive snow or ice build up may occur. Be sure to check vent the side wall, or vertically through the roof. termination area after snow falls, and clear to prevent •...
BDVT Series Direct Vent Gas Fireplace General Venting Information - Termination Location INSIDE CORNER DETAIL Fixed Fixed Closed Closed Fixed Operable Closed AREA WHERE TERMINAL IS NOT PERMITTED VENT TERMINATION AIR SUPPLY INLET CFM145a Canadian Installations US Installations A = Clearance above grade, veranda, porch, 12”...
BDVT Series Direct Vent GaS Fireplace Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Recessed Location Outside Corner Combustible 6"(152mm) Combustible 6"(152mm) Noncombustible 2"(52mm) Noncombustible 2"(52mm) Balcony - Balcony - with no side wall with perpendicular side wall C = Maximum depth of 48"...
BDVT Series Direct Vent Gas Fireplace How to Use the Vent Graph Vertical Sidewall Applications The vent chart should be read in conjunction with the Since it is very important that the venting following vent installation instructions to determine the system maintain its balance between the relationship of the vertical and horizontal dimensions of combustion air intake and the flue gas...
Page 14
BDVT Series Direct Vent Gas Fireplace STEP 2 STEP 5 Measure wall thickness and cut zero clearance sleeve Measure the horizontal length requirement including a parts to proper length (MAXIMUM 12”/305 mm). As- 2” (51mm) overlap, ie from the elbow to the outside wall semble sleeve and attach to firestop with #8 sheet face plus 2”...
BDVT Series Direct Vent GaS Fireplace STEP 7 measurement is taken from the collar of the fireplace (or transition elbow) to the face of the exterior wall. Apply high temperature sealant to 4” (102mm) and 7” Refer to the Sidewall Vent Graph for extended (179mm) collars or the termination one inch away from horizontal run if the vertical rise exceeds 24”...
BDVT Series Direct Vent Gas Fireplace Example: Maximum horizontal length 0 x 45° elbows = 10’ 93m0 1 x 45° elbows = 8¹⁄₂’ (2.6m) 2 x 45° elbows = 7’ (2.1m) • A minimum of an 8’ (2.4m) vertical rise. Snorkel •...
Vertical Restrictor Plate The legs of the restrictor (33BDVT only) plate must go down. When installing the 33BDVT with a Vertical Through- the-Roof configured flue system the restrictor plate, (#10002495) supplied with the appliance MUST BE FITTED TO THE APPLIANCE at installation.
Page 18
BDVT Series Direct Vent Gas Fireplace 7. Install roof support (Fig. 31) and roof flashing making sure upper flange of flashing is below the shingles. (Fig. 32) Min. 8. Install appropriate pipe sections until the venting is 2’ (610 mm) above the flashing.
BDVT Series Direct Vent GaS Fireplace Twist Lock Venting Components 7TDVRVT-Through the wall Rear Vent Termination Starter Kit-Model7TDVSK-Sidewall Venting Starter Kit-Model 7TDVSKV-Vertical Venting for 7TDVSKV-A order 1/12 to 6/12 roof pitch for 7TDVSKV-B order 7/12 to 12/12 roof pitch for 7TDVSKV-F order flat roof Starter Kit-Model 7TDVSKS-Snorkel Kit Snorkel Termination - 7TDVSNORK for Below Grade Installation...
BDVT Series Direct Vent Gas Fireplace Operating Instructions Glass Information Only glass approved by CFM Specialty Home Products should be used on this fireplace. • The use of any non-approved replacement glass will void all product warranties. • Care must be taken to avoid breakage of the glass. •...
The individual logs can be identified by numbers cast on the underside of each log. Log Identification Chart 33BDVT Embers LG268 Fig. 36 33BDVT log placement. Location 33BDVT 36BDVT 39BDVT 43BDVT Front Left BB11...
Page 22
Do not place any of the lava rock 8. Scatter the lava rock material around the firebox material on the burner housing base. assembly. Do not place any of the lava rock material on the burner housing assembly. 33BDVT BC13 BC10 43BDVT BD13 BD11 Embers...
BDVT Series Direct Vent Gas Fireplace Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit Follow the gas supplier's instructions.
Page 25
BDVT Series Direct Vent GaS Fireplace Lighting and Operating Instructions For Fireplaces equipped with SIT822 Gas Valve (EN or EP) Warning: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury and loss of life. FOR YOUR SAFETY READ THE FOLLOWING WARNINGS BEFORE LIGHTING THE APPLIANCE Follow the gas suppliers instructions.
BDVT Series Direct Vent Gas Fireplace Troubleshooting Honeywell Millivolt Valve Remove Window Frame Assembly Before Service Work START CHECK • Supply Line Hooked Up Gas Supply On • Shutoff Valve Open • Lockout Has Engaged. Wait 60 Seconds And Try Again. •...
Page 27
BDVT Series Direct Vent GaS Fireplace Troubleshooting the Gas Control System SIT NOVA 820 MILLIVOLT VALVE NOTE: Before trouble shooting the gas control system, be sure external gas shut off is in the “On” position. WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE GLASS FRONT. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION...
Page 28
BDVT Series Direct Vent Gas Fireplace Troubleshooting the Gas Control System SIT 822 Valve with a Honeywell Electronic Ignitor START •TURN GAS SUPPLY OFF CHECK: • LINE VOLTAGE (120VAC) • LOW VOLTAGE TRANSFORMER • TURN ON/OFF SWITCH (19.5 minimum VAC) TO CALL FOR HEAT "ON"...
BDVT Series Direct Vent GaS Fireplace Do not over-tighten the screw, it must be finger CONVERTING THE APPLIANCE FROM LP TO tight. NATURAL GAS OR NATURAL GAS TO LP d) Refit the regulator cap. e) Mount the conversion label supplied with The conversion of this appliance from one gas to conversion screw to the valve in a visible posi- another must be carried out by an authorized...
BDVT Series Direct Vent Gas Fireplace Maintenance Burner and Burner Compartment To obtain proper operation, it is imperative that the pilot and burner’s flame characteristics are steady, not It is important to keep the burner and the burner lifting or floating. compartment clean.
BDVT Series Direct Vent GaS Fireplace 4a/b 3a/b 12a/b 33BDVT 14a/b 36BDVT 13a/b 2a/b 43BDVT 39BDVT CFM Specialty Home Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, with out notice.
Page 32
BDVT Series Direct Vent Gas Fireplace BDVT (continued) (Items marked “*” are not shown.) Ref. Description 33BDVT 36BDVT 39BDVT 43BDVT Log Set (complete) 10003685 10003353 100003354 10003696 Log - Front left BB11 BC11 BD12 Log - Front right BB12 BD14...
Page 33
BDVT Series Direct Vent GaS Fireplace BDVT (continued) (Items marked “*” are not shown.) Ref. Description 33BDVT 36BDVT 39BDVT 43BDVT Fan speed control, (FK24 option) 51738 51738 51738 51738 Knob, fan speed control, (FK24 option) 51882 51882 51882 51882 Fan assembly, with bracket (FK12 option)
BDVT Series Direct Vent Gas Fireplace Optional Accessories Fan Kits Thermal Sensor FK24 Fan Assembly This auxiliary fan system increases the efficiency of the circulation of the heating air. The FK24 fan kit allows variable speed control of the circulation fan and also incorporates a heat sensor in the circuit.
Ceramic Refractory Kits Panel Ceramic refractory panels are available in kit form for Firebox Back the BDV series appliances Panel Rear Panel Appliance Model Kit Name Support Brackets 33BDVT AT1TBT 33BDVR AT1CBB 36BDVT BT2CBB Rear Log 39BDVT CT2CBB Support 43BDVT...
Fig. 54 Bay window installation. Window Frame Assembly Bay Window Screen Bay Window Screen Kits are available for the 33BDVT, 36BDVT, 39BDVT & 43BDVT model appliances. Do not remove existing window frame assembly! Remove all plastic from brass trims.
LIMITED LIFETIME WARRANTY PRODUCT COVERED BY THIS WARRANTY All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic or Northern Flame brand gas fireplaces equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner. BASIC WARRANTY Any part and/or component replaced under the provisions of this •...
Need help?