CHECk GAS PRESSURE

Connecting directly to an unregulated
propane/LPG tank can cause an
explosion
The stainless flex line is on the right side facing the fire-
place and can connect to either a 3/8 NPT female or 1/2
NPT male pipe. To connect from the opposite side, route
the pipe under the rear portion of the unit.
Test all gas joints from the gas meter to the heater valve
for leaks using a gas analyzer or soap and water solution
after completing connection. DO NOT USE AN OPEN
FLAME.
Check the gas pressure with the appliance burning and
the control set to HIGH.
Open control access door on either side of unit to find valve
and regulator referred to below. Page 12, Figure 14
23D8036
33ISDG Vent Free Gas Fireplace System
MILLIVOLT CONTROL
Figure 15
The valve regulator controls the burner pressure which
should be checked at the pressure test point.
Turn captured screw counter clockwise two or three turns
and then place tubing to pressure gauge over test point
(Use test point "OUT" closest to control knob). After taking
pressure reading, be sure and turn captured screw clock-
wise firmly to re-seal. Do not over torque. Check for gas
leaks.
Test Port
"OUT"
Figure 15 -
Pressure Test Point Location
Millivolt Control
FP2781