Majestic 300DVBNV7 Installation And Operation Instructions Manual

Dvb7 series direct vent gas fireplace
Table of Contents

Advertisement

DVB7 Series
Direct Vent Gas Fireplace
Models:
300DVBN/PV7;N/PSC7, 400DVBN/PV7;N/PSC7,
500DVBN/PV7;N/PSC7, 600DVBN/PV7;N/PSC7
WARNING
IF the INFoRMAtIoN IN theSe INStRuCtIoNS IS Not
FolloWeD exACtly, A FIRe oR exPloSIoN MAy
ReSult CAuSING PRoPeRty DAMAGe, PeRSoNAl
INjuRy oR loSS oF lIFe.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
WhAt to Do IF you SMell GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
WARNING: Improper installation, adjustment, alteration,
services or maintenance can cause injury or property
damage. Refer to this manual. For assistance or additional
information consult a qualified installer, service agency
or the gas supplier.
this appliance may be installed in an aftermarket*,
permanently located, manufactured home (uSA only) or
mobile home, where not prohibited by local codes.
this appliance is only for use with the type of gas
indicated on the rating plate. this appliance is not
convertible for use with other gases, unless a certified
kit is used.
* Aftermarket: Completion of sale, not for purpose of resale, from the
manufacturer.
Due to hIGh teMPeRAtuReS, the APPlIANCe
547050
ShoulD Be loCAteD out oF tRAFFIC AND
AWAy FRoM FuRNItuRe AND DRAPeRIeS.
DVB7 cover
ChIlDReN AND ADultS ShoulD Be AleRteD
to t h e h A Z A R D S o F h I G h S u R FA C e
teMPeRAtuRe AND ShoulD StAy AWAy to
AVoID BuRNS oR ClothING IGNItIoN.
youNG ChIlDReN ShoulD Be SuPeRVISeD
WheN they ARe IN the SAMe RooM AS the
APPlIANCe.
ClothING oR otheR FlAMMABle MAteRIAl
ShoulD Not Be PlACeD oN oR NeAR the
APPlIANCe.
KeeP the RooM AReA CleAR AND FRee FRoM
CoMBuStIBle MAteRIAlS, GASolINe, AND
otheR FlAMMABle VAPoRS AND lIquIDS.
INStAlleR: leave this manual with the appliance.
CoNSuMeR: Retain this manual for future refer-
ence.
54D7051 1/10 Rev. 3

Advertisement

Table of Contents
loading

Summary of Contents for Majestic 300DVBNV7

  • Page 1 DVB7 Series Direct Vent Gas Fireplace Models: 300DVBN/PV7;N/PSC7, 400DVBN/PV7;N/PSC7, 500DVBN/PV7;N/PSC7, 600DVBN/PV7;N/PSC7 WARNING IF the INFoRMAtIoN IN theSe INStRuCtIoNS IS Not FolloWeD exACtly, A FIRe oR exPloSIoN MAy ReSult CAuSING PRoPeRty DAMAGe, PeRSoNAl INjuRy oR loSS oF lIFe. – Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2: Table Of Contents

    CoNteNtS DVB7 Series Direct Vent Gas Fireplace thank you and congratulations on your purchase of a Majestic Fireplace. PleASe ReAD the INStAllAtIoN AND oPeRAtIoN INStRuCtIoNS BeFoRe uSING the APPlIANCe! IMPoRtANt: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty.
  • Page 3: Important Safety Information

    IMPoRtANt SAFety INFoRMAtIoN DVB7 Series Direct Vent Gas Fireplace oWNeR INStAlleR Please retain these instructions for future reference. Please leave these instructions with the appliance. • Read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace. •...
  • Page 4: Code Approval

    DVB7 Series Direct Vent Gas Fireplace IMPoRtANt SAFety INFoRMAtIoN 14. Do not use any solid fuels (wood, coal, paper, card- IMPoRtANt: board, etc.) in this fireplace. Use only the gas type PleASe ReAD the FolloWING indicated on rating plate. CAReFully 15.
  • Page 5: Product Features

    Max.Input Min. Input Orifice natural or propane gas. Refer to appropriate data Model Fuel BTU/h BTU/h Size plates. 300DVBNV7 Nat. 1,000 15,000 • This appliance is not for use with solid fuels. 300DVBPV7 1,000 15,000 • The appliance is approved for bedroom or bedsitting 300DVBNSC7 Nat.
  • Page 6: Fireplace & Framing Dimensions

    FIRePlACe DIMeNSIoNS DVB7 Series Direct Vent Gas Fireplace Min. Rough Opening  Depth 1/2” 5/8” 1/2” 5/8” 1/2” or 5/8” O - Min. Rough Opening Width Min. Rough Opening Height 1/2” 5/8" Figure 2 - 3 ” Fireplace and Framing Dimensions 8 ” 300DVB 400DVB 500DVB 600DVB 33Z\zn” (840 mm) 37Z\zn”...
  • Page 7: Fireplace Location

    PRe-INStAllAtIoN INFoRMAtIoN DVB7 Series Direct Vent Gas Fireplace FIReBox FRAMING Firebox framing can be built before or after the appliance is set in place. Refer to Figure 2 for fireplace and framing Do not fill spaces around firebox with dimensions. Construct firebox framing following Figure 2 insulation or other materials.
  • Page 8: Clearances

    CleARANCeS DVB7 Series Direct Vent Gas Fireplace CleARANCeS to CoMBuStIBleS Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard. the appliance cannot be installed on a carpet, tile or other combustible material other than wood flooring.
  • Page 9: Secure Fireplace To Floor Or Framing

    SeCuRe FIRePlACe to FlooR or FRAMING DVB7 Series Direct Vent Gas Fireplace The fireplace must be secured to the floor and/or to framing studs as shown in Figure 6. Use two () wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) screws to attach fireplace to framing.
  • Page 10: Optional Top Vent Application

    oPtIoNAl toP VeNt APPlICAtIoN DVB7 Series Direct Vent Gas Fireplace oPtIoNAl toP VeNt APPlICAtIoN After conversion to top vent configuration, the The appliance is shipped as a rear vent unit. If the instal- 4” (102 mm) flue pipe should be concentric lation layout requires the unit to be a top vent configu- within the 6B\,”...
  • Page 11: Vent Installation

    VeNtING INStAllAtIoN INFoRMAtIoN DVB7 Series Direct Vent Gas Fireplace Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life. operation of improperly installed and maintained venting system could result in serious injury, property damage or loss of life.
  • Page 12: Termination Location

    DVB7 Series Direct Vent Gas Fireplace VeNtING INFoRMAtIoN GeNeRAl VeNtING INFoRMAtIoN - teRMINAtIoN loCAtIoN INSIDE  CORNER DETAIL  G  V  H  A  D  E  L  C  B  B  V  Fixed B  V  Closed V  Fixed Operable Closed F  V  B  M  V  B ...
  • Page 13: Termination Clearances

    VeNtING INFoRMAtIoN DVB7 Series Direct Vent Gas Fireplace Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Alcove Applications* Outside Corner Combustible 6" (152 mm) Combustible 6" (152 mm) Noncombustible 2" (51 mm) Noncombustible 2" (51 mm) Balcony - Balcony - with no side wall...
  • Page 14: Vent Graph

    VeNtING INFoRMAtIoN DVB7 Series Direct Vent Gas Fireplace tWISt loCK PIPeS When using twist lock pipe it is not necessary to use sealant on the joints. The only areas of the venting system that need to be sealed with high temperature silicone sealant are the sliding joints of any telescopic vent section used in the system.
  • Page 15 VeNt INStAllAtIoN DVB7 Series Direct Vent Gas Fireplace horizontal sections of this vent system this fireplace must be vented to the require a minimum of 3” clearances to outside. the venting system must NeVeR combustibles at the top of the flue and 1” be attached to a chimney serving a clearance at the sides and bottom until separate solid fuel burning appliance.
  • Page 16: Rear Wall Vent Applications & Installation

    VeNtING INStAllAtIoN DVB7 Series Direct Vent Gas Fireplace ReAR WAll VeNt APPlICAtIoN Vent opening for Combustible Walls 9B\,” When installed as a rear vent unit this appliance may be (44 mm) Min. vented directly to a termination located on the rear wall behind the appliance.
  • Page 17: Top Vent Sidewall Applications & Installation

    VeNt INStAllAtIoN DVB7 Series Direct Vent Gas Fireplace Finish Wall Vent Rise Termination FP147 Figure 20 - There must be a 1/2" rise per foot length toP VeNt SIDeWAll APPlICAtIoN Figure 18 - FP94 Note: For all top vent installations where a 90° elbow Side View of Final Unit Location is the first pipe piece towards a sidewall termination (up FP1472...
  • Page 18 VeNtING INStAllAtIoN DVB7 Series Direct Vent Gas Fireplace • The maximum number of elbow degrees in a system is When installing the appliance as a rear vent unit, the 70°. Figure 26 90° or 45° transition elbow attached directly to the Example: Elbow 1 = 90°...
  • Page 19: Vertical Sidewall Installation

    VeNtING INStAllAtIoN DVB7 Series Direct Vent Gas Fireplace VeRtICAl SIDeWAll INStAllAtIoN - tWISt loCK PIPe Step 1 Locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole lo- cation. Depending on whether the wall is combustible or noncombustible, cut opening to size.
  • Page 20 DVB7 Series Direct Vent Gas Fireplace VeNtING INStAllAtIoN Step 7 Guide the vent terminations 4” and 7” collard into their respective vent pipes. Double check that the vent pipes overlap the collars by ” (51 mm). Secure the termina- 4” Flex Vent Pipe tion to the wall with screws provided and caulk around 12"...
  • Page 21: Below Grade Installation

    DVB7 Series Direct Vent Gas Fireplace VeNtING INStAllAtIoN BeloW GRADe INStAllAtIoNS 6. Slide the snorkel into the vent pipes and secure to the wall. When it is not possible to meet the required vent terminal 7. Level the soil so as to maintain a 4" clearance below clearances of 1"...
  • Page 22: Vertical Through-The-Roof Installation

    VeNtING INStAllAtIoN DVB7 Series Direct Vent Gas Fireplace VeRtICAl thRouGh-the-RooF INStAllAtIoN Note: For all top vent vertical through-the-roof installa- Max.Height 40’ (1.. m) tions, install the supplied cross-bar flue restrictor onto the Min. Height top edge of the firebox flue adapter. Figure 36 8’...
  • Page 23 VeNtING INStAllAtIoN DVB7 Series Direct Vent Gas Fireplace 10. Add additional vent lengths for proper height. Figure Horizontal Overhang 11. Apply high temperature sealant to 4” and 7” collars of vertical vent termination and install. 2 ft.  2 ft. Min. If there is a room above ceiling level, fire stop spacer must Min.
  • Page 24: Check Gas Type

    DVB7 Series Direct Vent Gas Fireplace FIRePlACe INStAllAtIoN CheCK GAS tyPe Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace for your gas type or conversion kit.
  • Page 25 DVB7 Series Direct Vent Gas Fireplace FIRePlACe INStAllAtIoN A manual shutoff valve must be installed only persons licensed to work with gas upstream of the appliance. union tee and piping may make the necessary gas plugged 1/8” NPt pressure tapping point connections to this appliance.
  • Page 26: Check Gas Pressure - Millivolt

    DVB7 Series Direct Vent Gas Fireplace MIllIVolt CheCK GAS PReSSuRe and eleCtRICAl INStAllAtIoN 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, StoP! Do not install the appliance.
  • Page 27: Electrical Installation

    eleCtRICAl INStAllAtIoN DVB7 Series Direct Vent Gas Fireplace ReMote WAll MouNteD SWItCh A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in a junction box at the desired location on the wall. Figure 44. Do not extend beyond the wall switch wire length provided.
  • Page 28: Optional Fan/Blower Systems - Milli-Volt

    DVB7 Series Direct Vent Gas Fireplace oPtIoNAl FAN / BloWeR SySteM oPtIoNAl FAN/BloWeR SySteMS (Blot) Installation Instructions Wiring 1. Before installing the blower, wire the receptacle into an electrical circuit. This should be done be- fore framing the fireplace. Wire with minimum 60° C wire in accordance with prevailing codes. .
  • Page 29: Operating Instructions (Millivolt)

    oPeRAtING INStRuCtIoNS (MIllIVolt) DVB7 Series Direct Vent Gas Fireplace FoR youR SAFety ReAD BeFoRe lIGhtING If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with a pilot which must be lit with built-in piezo ignitor while following these instructions exactly.
  • Page 30: Lighting Pilot

    oPeRAtING INStRuCtIoNS (MIllIVolt) DVB7 Series Direct Vent Gas Fireplace lIGhtING PIlot FoR the FIRSt tIMe APPRoVeD leAK teStING MethoD If using a soap and water You may check for gas leaks with the following methods solution to test for leaks, only: Do Not spray solution onto •...
  • Page 31: Lighting Burner

    oPeRAtING INStRuCtIoNS (MIllIVolt) DVB7 Series Direct Vent Gas Fireplace lIGhtING BuRNeR MAIN BuRNeR SWItCh The “ON/OFF/RS” switch for the main burner can be found behind door of the fireplace. This switch allows you to turn on and to turn off the main burner without using the gas valve knob. Make sure the button is in the “ON”...
  • Page 32: Check Gas Pressure - Signature Command System

    SIGNAtuRe CoMMAND - CheCK GAS PReSSuRe and eleCtRICAl INStAllAtIoN DVB7 Series Direct Vent Gas Fireplace 1. Check gas type. The gas supply must be the same as Pressure Inlet stated on the appliance’s rating decal. If the gas supply is different from the fireplace, StoP! Do not install the appliance.
  • Page 33: Electrical Wiring - Signature Command System

    eleCtRICAl INStAllAtIoN DVB7 Series Direct Vent Gas Fireplace juNCtIoN Box WIRING 1. This should be done before framing the fireplace. Wire the receptacle into an electrical circuit. Wire with minimum 60° C wire in accordance with prevailing codes. . Remove the external junction box cover by removing the screw from the side of the outside firebox wall.
  • Page 34: Signature Command Wiring Diagram

    DVB7 Series Direct Vent Gas Fireplace SIGNAtuRe CoMMAND - eleCtRICAl INStAllAtIoN Optional To Junction Box AC Module in Fireplace Pilot Optional White Light Black Optional White Blower Black White Optional Black Aux. Green Connector Pin To Control Board Input 300 Watt Max. Each Optional A/C Module Replaces 6V Adapter When Used RF Receiver ON/OFF Button Control Board 6V AC Black / Thermopile Adapter Red / Thermopile Sensor Conversion...
  • Page 35: Blotsc Signature Command System

    oPtIoNAl FAN BloWeR SySteM DVB7 Series Direct Vent Gas Fireplace electrical Grounding Instructions: this electrical connections should only be appliance is equipped with a three-prong performed by a qualified licensed electrician. (grounding) plug for your protection against Main power supply must be turned off before shock hazard and should be plugged directly connecting the fan to the main electrical into a properly grounded three-prong...
  • Page 36: Optional Fan/Blower Systems

    DVB7 Series Direct Vent Gas Fireplace oPtIoNAl FAN BloWeR SySteMS Blot AutoMAtIC theRMoStAt BloWeR 120VAC Receptacle  Junction  BLACK GREEN FP675 WHITE BLACK WHITE BLACK BLACK Speed Control  Before installing the blower, wire the receptacle into an Figure 55 - electrical circuit. This should be done before framing the BLOT Blower Wiring Diagram fireplace.
  • Page 37: Operating Instructions - Signature Command System

    oPeRAtING INStRuCtIoNS - SIGNAtuRe CoMMAND DVB7 Series Direct Vent Gas Fireplace FoR youR SAFety ReAD BeFoRe lIGhtING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of lie. A.
  • Page 38: Operating Instructions

    oPeRAtING INStRuCtIoNS - SIGNAtuRe CoMMAND DVB7 Series Direct Vent Gas Fireplace oPeRAtING INStRuCtIoNS 1. StoP! Read the safety information above. . This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 3.
  • Page 39: Signature Command System Operation

    SIGNAtuRe CoMMAND SySteM oPeRAtIoN INStRuCtIoNS DVB7 Series Direct Vent Gas Fireplace FeAtuReS To Thermopile RF Receiver ON/OFF To Sensor Command Center To Sparker • Easy Access Function Operation and System Configuration • Operation Confirmation/Fault Diagnostic Indications (LED/ NG/LP Buzzer) Conversion •...
  • Page 40: System Configuration/Setup

    SIGNAtuRe CoMMAND SySteM oPeRAtIoN INStRuCtIoNS DVB7 Series Direct Vent Gas Fireplace SySteM CoNFIGuRAtIoN/SetuP All System configuration/setup is done on the Command Center. Note: When using On/Off wall switch, the switch must be in the ON position to perform all configuration set ups at the command center.
  • Page 41 SIGNAtuRe CoMMAND SySteM oPeRAtIoN INStRuCtIoNS DVB7 Series Direct Vent Gas Fireplace FuNCtIoNS/oPeRAtIoN turning on the fireplace 1. Turn on the master switch and wait for a beep. . Press the ON button on the Command Center or turn on wall switch. Pilot will light and burner will come on High set- ting or last memory setting (See Turning Off Fireplace below).
  • Page 42: Glass Removal

    GlASS ReMoVAl DVB7 Series Direct Vent Gas Fireplace GlASS FRAMe ReMoVAl 1. Release two clamps on bottom of fireplace. Figure 58 . Tilt glass frame out and lift glass frame up until it clears three tabs on top of fireplace. 3.
  • Page 43: Final Installation

    FINAl INStAllAtIoN DVB7 Series Direct Vent Gas Fireplace Burner RoCK Wool PlACeMeNt 1. For best results in flame appearance and operation, use one (1) 8 gram bag of rock wool for propane/LP models and up to three (3) bags of rock wool for natural gas models. .
  • Page 44: Cleaning And Maintenance

    CleANING and MAINteNANCe DVB7 Series Direct Vent Gas Fireplace Thermocouple turn off gas before servicing fireplace. It Thermopile is recommended that a qualified service Millivolt Control technician perform these check-ups at the Pilot beginning of each heating season. BuRNeR, PIlot AND CoNtRol CoMPARt- MeNt Keep the control compartment, logs, and burner areas surrounding the logs clean by vacuuming or brushing at...
  • Page 45: Vent System

    CleANING and MAINteNANCe DVB7 Series Direct Vent Gas Fireplace VeNt SySteM The fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the airflow.
  • Page 46: Troubleshooting

    tRouBleShootING DVB7 Series Direct Vent Gas Fireplace StANDING PIlot IGNItIoN SyMPtoM PoSSIBle CAuSe ACtIoN 1. Spark ignitor will A. Wire disconnected. A. Open door and check to make sure wire is connected not light pilot after to ignitor. repeated triggering of B.
  • Page 47 tRouBleShootING DVB7 Series Direct Vent Gas Fireplace StANDING PIlot IGNItIoN SyMPtoM PoSSIBle CAuSe ACtIoN 4. Frequent pilot A. Pilot flame may be too high A. Clean and adjust the pilot flame for maximum flame outage problem. or too low, causing pilot impingement on thermocouple.
  • Page 48: Signature Command System

    tRouBleShootING DVB7 Series Direct Vent Gas Fireplace SIGNAtuRe CoMMAND SySteM ACTION OPERATION FAULT DIAGNOSIS Using Battery polarity wrong? Re-install batteries battery? Make sure Command Install batteries and/or Battery voltage low? Change batteries Center and plug in the AC board No beep in about the control 8 seconds board are...
  • Page 49: Replacement Parts

    RePlACeMeNt PARtS DVB7 Series Direct Vent Gas Fireplace FIReBox CoMPoNeNtS 540701 DVB parts 54D7051...
  • Page 50 RePlACeMeNt PARtS DVB7 Series Direct Vent Gas Fireplace FIReBox CoMPoNeNtS Item Description qty. 300DVB 400DVB 500DVB 600DVB Standard Features Junction Box 6D18K 6D18K 6D18K 6D18K Black Louver 54D046 6D0695 6D0697 6D0699 Glass Frame Assembly 54D094 54D0195 54D0340 54D0443 Factory Installed options Brass Louver 54D049K 6D0701K...
  • Page 51: Standing Pilot Millivolt Control

    RePlACeMeNt PARtS DVB7 Series Direct Vent Gas Fireplace StANDING PIlot - MIllIVolt CoNtRol 11,12,13,14 540701 DVB millivolt parts 54D7051...
  • Page 52 RePlACeMeNt PARtS DVB7 Series Direct Vent Gas Fireplace StANDING PIlot - MIllIVolt CoNtRol Item Description qty. 300DVBNV7 300DVBPV7 400DVBNV7 400DVBPV7 500DVBNV7 500DVBPV7 600DVBNV7 600DVBPV7 Gas Valve Assy. 37D0117 37D0118 37D0117 37D0118 37D0117 37D0118 37D0117 37D0118 Pilot Assembly 37D0018 37D0019 37D0018...
  • Page 53: Signature Command System

    RePlACeMeNt PARtS DVB7 Series Direct Vent Gas Fireplace SIGNAtuRe CoMMAND SySteM 13,14,15,16,17 540701 SC parts 54D7051...
  • Page 54 DVB7 Series Direct Vent Gas Fireplace RePlACeMeNt PARtS SIGNAtuRe CoMMAND SySteM Item Description qty. 300DVBNS7 300DVBPS7 400DVBNS7 400DVBPS7 500DVBNS7 500DVBPS7 600DVBNS7 600DVBPS7 1. Gas Valve Assy. 80D0001 80D000 80D0001 80D000 80D0001 80D000 80D0001 80D000 . Pilot Assembly 80D0006 80D0007 80D0006 80D0007 80D0006 80D0007...
  • Page 55: Logs

    RePlACeMeNt PARtS DVB7 Series Direct Vent Gas Fireplace loGS Ref. Description qty. 300DVB 400DVB 500DVB 600DVB 1. Rear Log #1 54D01 54D0117 54D0331 54D0331 . Bottom Left Log # 54D013 54D0118 54D0358 54D0358 3. Bottom Right Log #3 54D014 54D0119 54D0359 54D0359 4.
  • Page 56: Vertical Venting Components

    DVB7 Series Direct Vent Gas Fireplace RePlACeMeNt PARtS VeRtICAl VeNtING Description Model Number Vertical Vent Termination Kits Vertical Vent Termination w/ Storm Collar 7TDVSKV (flashing NOT included) Vertical Vent Termination w/ Storm Collar - 8 pack 7TDVSKV/8 (flashing NOT included) Vertical Vent Termination w/ 1/1 - 6/1 Flashing, Storm 7TDVSKVA* Collar and Ceiling Support Kit...
  • Page 57: Horizontal Venting Components

    RePlACeMeNt PARtS DVB7 Series Direct Vent Gas Fireplace hoRIZoNtAl VeNtING Description Model Number Horizontal Vent Termination Kits Up and Out Side Wall Termination Kit, includes 1” to 16” 7TBLSCTK Adjustable Termination Pipe, 90° Elbow, Firestops and Cool Touch Termination w/Siding Shield, Additional 1” Section Provided for Min.
  • Page 58: Massachusetts Residents Only

    Massachusetts Residents only — Please read and follow these special requirements DVB7 Series Direct Vent Gas Fireplace . Approved Carbon Monoxide Detectors. Each carbon Note ReGARDING VeNteD PRoDuCtS monoxide detector as required in accordance with the above This product must be installed by a licensed plumber or gas fitter provisions shall comply with NFPA 70 and be ANSI/UL 034 when installed within the Commonwealth of Massachusetts.
  • Page 59: Warranty

    DVB7 Series Direct Vent Gas Fireplace lIMIteD lIFetIMe WARRANty PolICy lIFetIMe WARRANty The following components are warranted for life to the original owner, subject to proof of purchase: Firebox, Combustion Chamber, Heat Exchanger, Grate and Stainless Steel Burners. FIVe yeAR WARRANty The following components are warranted five (5) years to the original owner, subject of proof of purchase: Ceramic Fiber Logs.
  • Page 60: Efficiencies

    DVB7 Series Direct Vent Gas Fireplace Based on CSA P.4.1-09 efficiency Ratings Model enerGuide Ratings Fireplace efficiency (%) 300DVBNV7 57.9 300DVBPV7 53.8 300DVBNSC7 61.8 300DVBPSC7 55.7 Recherchez dans la brochure 400DVBNV7 58.4 les caractéristique de rendement 400DVBPV7 58.5 énergétique de foyer au gaz 400DVBNSC7 61.1...

Table of Contents