Majestic 33BDVT Installation Instructions & Homeowner's Manual

Builder top vent direct vent models

Advertisement

I
NSTALLATION
WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS:
* Do not try to light any appliance.
* Do not touch any electric switch
* Do not use any phone in your building.
* Immediately call your gas supplier from
your neighbours phone. Follow the gas
suppliers instructions.
* If you cannot reach your gas supplier
call the re department
INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER
I
NSTRUCTIONS
410 Admiral Blvd. Mississauga, Ontario, Canada. L5T 2N6
www.majesticproducts.com / www.vermontcastings.com
Direct Vent Models
& H
OMEOWNER
FOR YOUR SAFETY
DO NOT STORE
OR USE GASOLINE OR OTHER
FLAMMABLE VAPOURS AND/OR
LIQUIDS IN THE VICINITY OF THIS OR
ANY OTHER APPLIANCE.
Installation and service must be performed
by a qualied installer, service agency or
your gas supplier.
Builder

Top Vent

33BDVT
36BDVT
39BDVT
43BDVT
'
M
S
ANUAL
10002555
05/00 Rev. 0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 33BDVT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Majestic 33BDVT

  • Page 1: Top Vent

    Builder Top Vent Direct Vent Models 33BDVT 36BDVT 39BDVT 43BDVT & H NSTALLATION NSTRUCTIONS OMEOWNER ANUAL WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
  • Page 2: Table Of Contents

    ABLE ONTENTS Thank You & Congratulations On Your Purchase of a Vermont Castings, Majestic Products Fireplace. Please Read The Installation & Operating Instructions Carefully before Using The Appliance. Important: Read all the instructions and warnings carefully before starting the installation. Failure to follow these instructions fully may result in a possible re hazard and will void the manufacturers...
  • Page 3: Appliance Installation Instructions Important Curing/Burning Instructions

    replace and should stay It is not unusual for your Majestic gas replace to give away to avoid burns or ignition of clothing. off some odour the rst time it is burned. This is due to...
  • Page 4: Fireplace Dimensions

    Vermont Castings, Majestic Products. PPLIANCE IMENSIONS Framing Dimensions Appliance Dimensions Appliance Dimensions Ref. 33BDVT 36BDVT 39BDVT 43BDVT 838 mm (33") 914 mm (36") 991 mm (39") 1092 mm (43") 733 mm (28.87") 870 mm (34.25") 870 mm (34.25") 940 mm (37") 416 mm (16.37")
  • Page 5: Clearance To Combustibles

    Vermont Castings, Majestic Products. LEARANCE TO OMBUSTIBLES Mantel Shelf Chart (Minimum Height) Appliance Ref. Mantel Depth Ref. Mantel Height Top......0 mm (0") 10" (254 mm) 12" (305 mm) Bottom....... 0 mm (0") 8" (203 mm) 10" (254 mm) Side......0 mm (0") 6"...
  • Page 6: Final Nishing

    Vermont Castings, Majestic Products. 33BDVT / 36BDVT / 39BDVT / 43BDVT CERTIFIED TO A = 1/2" (13 mm) Drywall ANSI Z21.88b-1999 / CSA Z2.33b-M99 B = 5/8" (16 mm) Drywall C = 3/4" (19 mm) Drywall Vented Gas Fireplace Heaters PECIFICATIONS Max.
  • Page 7: Gas Line Installation

    Vermont Castings, Majestic Products. ON/OFF S NSTALLATION EMOTE WITCH Installation When purging the gas lines, the front glass must 1. Thread the wiring through the holes on the end panels of be removed. the appliance. Take care not to cut the wire or insulation The gas pipeline can be brought in through the on metal edges.
  • Page 8: Electronic Gas Valve Wiring Instructions

    Vermont Castings, Majestic Products. EB-1 E LECTRICAL LECTRONIC ONTROL ALVE The replace, when installed, must be electri- This appliance may be tted with either a Synetek ignition cally connected and grounded in accordance module or a Honeywell ignition module. The method of...
  • Page 9: Converting The Appliance Between Gas Types

    Vermont Castings, Majestic Products. ONVERTING PPLIANCE ATURAL AS OR ATURAL AS TO The conversion of this appliance from one gas to another must be carried out by an authorized service provider. PILOT BLACK 1. Disconnect power to the unit and shut off the gas supply.
  • Page 10 Vermont Castings, Majestic Products. e) Mount the conversion label supplied with the conver- sion screw to the valve in a visible position. 10. Reassemble the replace in the reverse order, except for Regulator Cap the front glass. Leave this off until the unit has been checked for leaks and the gas supply line has been bled.
  • Page 11: Venting Installation Instructions General Venting Information - Terminal Location

    Vermont Castings, Majestic Products. — T ENERAL ENTING NFORMATION ERMINATION OCATION Do not locate termination hood where excessive snow or ice Your replace is approved to be vented either through the side build up may occur. Be sure to check vent termination area wall, or vertically through the roof.
  • Page 12: Termination Clearances

    Vermont Castings, Majestic Products. Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Recessed Location Outside Corner Combustible 6"(152mm) Combustible 6"(152mm) Noncombustible 2"(50mm) Noncombustible 2"(50mm) Fig. 13 Fig. 14 Balcony - Balcony - with no side wall with perpendicular side wall C = Maximum depth of 48"...
  • Page 13: Connecting Direct Vent Components

    Fig. 18 BEAD LOCATION Twist Lock Pipes When using Vermont Castings, Majestic Products Twist Lock pipe it is not necessary to use sealant on the joints. The only areas of the venting system that need to be sealed with high temperature silicone sealant are the collars on the replace and termination, and the sliding joint of any tele-...
  • Page 14: Vertical Sidewall Applications

    Vermont Castings, Majestic Products. • If a 90º elbow is used in the horizontal vent run (level ERTICAL IDEWALL PPLICATIONS height maintained) the maximum horizontal vent length is reduced by 36" (914 mm), (Fig. 22). This does not apply Since it is very important that the venting system if the 90º...
  • Page 15: Vertical Sidewall Installations

    Vermont Castings, Majestic Products. ERTICAL IDEWALL NSTALLATIONS STEP 1 Locate vent opening on the wall. It may be necessary to rst position the replace and measure to obtain hole location. Depending on whether the wall is combustible or non-combus- tible, cut opening to size. (Fig. 24) (For combustible walls rst frame in opening.
  • Page 16: Below Grade Installations

    Vermont Castings, Majestic Products. STEP 6 Use appropriate length of pipe sections - telescopic or xed - and install the horizontal vent sections. The sections which go through the wall are packaged with the starter kit, and can be cut to suit if necessary. (Fig. 28).
  • Page 17: Vertical Through-The-Roof Applications

    Vermont Castings, Majestic Products. DO NOT BACK FILL AROUND SNORKEL. ERTICAL HROUGH A CLEARANCE OF AT LEAST 4” MUST BE PPLICATIONS MAINTAINED BETWEEN THE SNORKEL AND THE SOIL This Gas Fireplace has been approved for, • Vertical installations up to 40' (12 m) in height. Up to a 10' horizontal vent run can be installed within the vent system using a maximum of two 90º...
  • Page 18 ESTRICTOR LATE (33BDVT ONLY When installing the 33BDVT with a Vertical Through-The- Roof congured ue system the restrictor plate, (#10002495) Ret the bafe assembly to the rebox, replacing the three supplied with the appliance MUST BE FITTED TO THE (3) screws and four (4) nuts.
  • Page 19: Vertical Through-The-Roof Installations

    Vermont Castings, Majestic Products. Install storm collar and seal around the pipe. ERTICAL HROUGH 10. Add additional vent lengths for proper height. Fig. 40. NSTALLATION 11. Apply high temperature sealant to 4" and 7" collars of vertical vent termination and install.
  • Page 20: Operating Instructions

    1. Turn the replace OFF (including the pilot). Only glass approved by Vermont Castings, 2. If the unit has been operating allow time for the compo- Majestic Products should be used on this re- nents to cool. place. 3. Remove the top louvre assembly.
  • Page 21: Installation Of Logs & Lava Rock

    Scatter the lava rock material around the rebox base. Do not place any of the lava rock material on the burner housing. 39BDVT Fig. 45 Log Identication Chart BD10 Location 33BDVT 36BDVT 39BDVT 43BDVT Front left Front right Rear Top left Top right BB10 BD10 43BDVT Fig.
  • Page 22: Flame & Temperature Adjustment

    Vermont Castings, Majestic Products. & T LAME EMPERATURE DJUSTMENT RN/RP & EN/EP Models For units equipped with ‘HI/LO’ valves the ame adjustment is accomplished by rotating the ‘HI/LO’ adjustment knob located near the centre of the gas control valve, Fig. 47 & 48...
  • Page 23: Lighting Instructions

    Vermont Castings, Majestic Products. LIGHTING AND OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a re or explosion may result causing property damage, personal injury or loss of life. A. This replace has a pilot which must be lit manu- neighbour's phone.
  • Page 24 Vermont Castings, Majestic Products. IGHTING AND PERATING NSTRUCTIONS For Fireplaces Equipped With SIT822 Gas Valve (EN or EP) WARNING: If you do not follow these instructions exactly, a re or explosion may result causing property damage, personal injury and loss of life.
  • Page 25: Troubleshooting Guide

    Vermont Castings, Majestic Products. TROUBLE SHOOTING THE GAS CONTROL SYSTEM HONEYWELL MILLIVOLT VALVE START CHECK • SUPPLY LINE HOOKED UP • GAS SUPPLY ON • SHUTOFF VALVE OPEN • LOCKOUT HAS ENGAGED. WAIT 60 SECONDS AND TRY AGAIN. • FOR SPARK AT ELECTRODE WHILE DEPRESSING PIEZO —...
  • Page 26 Vermont Castings, Majestic Products. TROUBLE SHOOTING THE GAS CONTROL SYSTEM SIT NOVA 820 MILLIVOLT VALVE Note: Before trouble shooting the gas control system, be sure external gas shut off is in the "On" position. WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE GLASS FRONT.
  • Page 27: Normal Operation

    Vermont Castings, Majestic Products. ROUBLE HOOTING ONTROL YSTEM SIT 822 Valve with a Synetek Electronic Ignitor Remove glass before servicing. Operating Diagram NORMAL OPERATION ABNORMAL OPERATION ON/OFF SWITCH CLOSED? 5 Sec. Inter-Trial Delay LED ON LOCKOUT: LED, STEADY FLASH. Reset by interrupting On/Off switch or SAFE START CHECK ON? Power for 10 seconds.
  • Page 28 Vermont Castings, Majestic Products. ROUBLE HOOTING ONTROL YSTEM SIT 822 Valve with a Honeywell Electronic Ignitor Remove glass before servicing. START •TURN GAS SUPPLY OFF CHECK: • LINE VOLTAGE (120VAC) • LOW VOLTAGE TRANSFORMER • TURN ON/OFF SWITCH (19.5 minimum VAC) TO "ON"...
  • Page 29: Replacement Parts

    Vermont Castings, Majestic Products. EPLACEMENT ARTS Items marked ‘*’ are not shown in the following parts pictorial page. Ref. Description 33BDVT 36BDVT 39BDVT 43BDVT Log Set (complete) 10000470 1000023 10000024 10000025 Log - Front left Log - Front right Log - rear...
  • Page 30 Vermont Castings, Majestic Products. 17b Gas Valve, Honeywell RP 10001759 Gas Valve, SIT822 EN 57884 57884 57884 57884 18b Gas Valve, SIT822 EP 57883 57883 57883 57883 Sensing electrode (with cable) EN & EP 57885 57885 57885 57885 Transformer, EN & EP...
  • Page 31: Parts Pictorial

    Vermont Castings, Majestic Products. ARTS ICTORIAL 3a/b 5a/b 4a/b 6a/b 16a/b 33BDVT 18a/b 36BDVT 17a/b 2a/b 43BDVT 39BDVT 10002555/0 -31- 33/36/39/43 BDVT...
  • Page 32: Optional Accessories

    Vermont Castings, Majestic Products. PTIONAL CCESSORIES VAILABLE FK12 This auxiliary fan system increases the efciency of the circu- lation of the heating air. FK24 Fan Assembly The FK12 Fan Assembly is a xed speed fan system and does This auxiliary fan system increases the efciency of the circu- not allow for variable speed control.
  • Page 33: Ceramic Refractory Lining

    Vermont Castings, Majestic Products. The second terminal of the speed control unit is attached Adjustable to either terminal of the thermal sensor. Adjustable The second terminal of the thermal sensor is connected to either terminal of the fan motor. The second fan motor terminal is connected to the white...
  • Page 34: Decorative Bay Window

    Fig. 58 Screen assembly ECORATIVE INDOWS Bay window kits are available for the 33BDVT, 36BDVT & 39BDVT model appliances. When tting the Bay Window Kits the original front frame/glass assembly MUST remain in place. The Bay Window kit is tted over the existing front glass.

This manual is also suitable for:

36bdvt39bdvt43bdvt

Table of Contents

Save PDF