Majestic 33ISDG Installation And Operating Instructions Manual page 9

Vent-free fireplace system
Table of Contents

Advertisement

CLEARANCES
HEAT RESISTANT MATERIAL (MINIMUM
REQUIREMENTS) WITH NO WOODEN MANTEL
OR OTHER COMBUSTIBLE PROjECTION
Heat resistant material (minimum requirements) with
wooden mantel or other combustible projection:
To install the heater with a wooden mantel shelf or other
combustible projection above, first measure the heat resis-
tant material shown in Figure 5.
Figure 5 -
Measure Heat Resistant Material for Mantel
FP2772
mantel material
12"
10"
8"
6"
2 "
Figure 6 -
Minimum Mantel Clearances
FP2773
23D8036
FP2773
Min mantel clearances
No combustible
materials within 8"
of opening.
Do not cover
louvers.
Hood
Grate
FP2772
26"
14"
Example: A mantel may
10"
project from the wall a maxi-
mum of 2Z\x" at minimum
8"
of 8" above the opening,
and a maximum of 12" at a
minimum of 26" above the
opening.
33ISDG Vent Free Gas Fireplace System
Figure 7 is an example of an unsafe mantel installation.
The mantel projects 4" at 8" above the opening, exceed-
ing the maximum acceptable distance of 2Z\x". The mantel
also projects 8" at 10" above the opening, exceeding the
maximum acceptable distance of 6".
If your mantel profile is unsafe, you may either:
Raise the mantel to an acceptable height or,
Remove the mantel.
No combustible
materials within 8" of
opening.
Do not cover louvers.
FP2773
Figure 7 -
Unsafe Mantel Clearances
FP2774
unsafe mantel
8"
6"
2
/
"
1
2
4"
10"
8"
Hood
9