Displaying the Status of a Single System Component
Before you remove a component that is duplexed for fault tolerance, verify that it is not in a simplex
state. To verify the state of a component, type a command in the following format:
ftsmaint ls path
For path, specify the correct value for the component, as listed in Table 1.
The value of Op State specifies whether the device is in a simplex state: the value is generally either
DUPLEX or SIMPLEX.
The following examples demonstrate some common commands and the resulting output.
In Example 2, the PCI module 1 is listed as having a State of ONLINE and an OP State of DUPLEX.
The value of SECONDARY for Reason indicates that it is operating as the backup I/O element
Example 2. Viewing the State of the Bottom PCI module
# ./ftsmaint ls 11
H/W Path
Description
State
Op State
Reason
Modelx
Artwork Rev
ECO Level
Min Partner ECO Level
Serial #
Active Compat Node
Logic Revision
MTBF Policy
MTBF fault class
Fault Count
Last Timestamp
Replace Threshold
Evict Threshold
Value
Minimum Count
Installing and Using Utilities 5-23
: 11
: Combined CPU/IO
: ONLINE
: DUPLEX
: SECONDARY
: 243-633635
: 0
: 0
: 0
: 2BA060026
: false
: 346
: useThreshold
: uncorrectable
: 0
: -
: 0
: 21600
: 0
: 4

Advertisement