1-6-8 PWBs
(1) Detaching and refitting the main PWB
Perform the following procedure when the main PWB is to be checked or replaced.
Procedure
1. Remove the top cover (see page 1-6-2).
2. Remove the left cover (see page 1-6-3).
3. Remove the right cover (see page 1-6-4).
4. Remove all (ten) connectors from the main
PWB.
5. Remove the five screws and then the main
PWB cover.
6. Remove the seven screws and then the main
PWB.
7. Check or replace the main PWB.
8. Refit all the removed parts.
Connectors
Screws Main PWB
Main PWB cover
Screws
Figure 1-6-30
Screws
Screws
Figure 1-6-31
FS-6020
Screw
Screws
1-6-25