Kyocera Mita FS-6020 Service Manual page 129

Kyocera mita fs-6020 laser printer service manual
Hide thumbs Also See for FS-6020:
Table of Contents

Advertisement

Connector Pin No.
YC1
1
+5V
2
VPP
Connected
3
WRSO
to the ROM
4
WRSI
writer
5
SCK
6
RSTN
7
GND
YC3
1
+24V
2
FANDRN
Connected
to the
cooling fan
motor
YC4
1
+24V1
2
+24V1
Connected
3
GND
to the
4
GND
power
5
HVGND
source
6
+24V2
PWB
7
ZCROSS
8
HEATONN
9
+5V1
10
+5V1
11
+24V
YC6
1
ANODE
2
GND
Connected
3
HANDSN
to the MP
tray feed
sensor
YC7
1
CAS2
2
CAS1
Connected
3
GND
to the
4
CAS1
cassette
size switch
YC8
1
+5V1
2
TNEMPN
Connected
3
GND
to the toner
sensor
YC9
1
+5V1
2
PFANDRN
Connected
to the
power
source fan
motor
YC10
1
+5V3
2
PAPVOL1
Connected
3
PAPVOL2
to the paper
4
GND
gauge
sensor
YC11
1
GND
2
EXITPAP
Connected
3
+5V1
to the eject
sensor
Signal
I/O
I
5 V DC
-
Ground
I
0/5 V DC(pulse)
O
0/5 V DC(pulse)
I
0/5 V DC(pulse)
I
0/5 V DC
-
Ground
O
24 V DC
O
0/24 V DC
I
24 V DC
I
24 V DC
-
Ground
-
Ground
-
Ground
I
24 V DC
I
0/5 V DC (pulse)
O
0/5 V DC
I
5 V DC
I
5 V DC
I
24 V DC
O
5 V DC
-
Ground
I
0/5 V DC
I
0/5 V DC
I
0/5 V DC
-
Ground
I
0/5 V DC
O
5 V DC
I
0/5 V DC
-
Ground
O
DC5V
O
DC0V/3.75V/5V
O
5 V DC
I
0/5 V DC
I
0/5 V DC
-
Ground
-
Ground
I
0/5 V DC
I
5 V DC
Voltage
5 V DC power
Ground
Data input signal
Data output signal
Clock signal for read/write
Reset signal
Ground
24 V DC power supply for cooling fan motor
Cooling fan motor: On/Off
24 V DC power input (via rear cover interlock switch)
24 V DC power input (via rear cover interlock switch)
Ground
Ground
Ground for high voltage
24 V DC power input
Zero-cross signal
Fixing heater lamp ON signal
5 V DC power input
5 V DC power input
24 V DC power input
5 V DC power supply for MP tray feed sensor
Ground
MP tray feed sensor: On/Off
Cassette size switch (SW2): On/Off
Cassette size switch (SW1): On/Off
Ground
Cassette size switch (SW0): On/Off
5 V DC power supply for toner sensor
toner sensor: On/Off
Ground
5 V DC power supply for power source fan motor
Power source fan motor: High speed/Low speed/Off
5 V DC power supply for paper gauge sensor
Paper gauge sensor 1: On/Off
Paper gauge sensor 2: On/Off
Ground
Ground
Eject sensor: On/Off
5 V DC power supply for eject sensor
FS-6020
Description
2-3-9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents