Explorer III Wood Stove
A. Congratulations
Hearth & Home Technologies welcomes you to our tradition
of excellence! In choosing a Quadra-Fire appliance, you
have our assurance of commitment to quality, durability, and
performance.
This commitment begins with our research of the market,
including 'Voice of the Customer' contacts, ensuring we
make products that will satisfy your needs. Our Research
and Development facility then employs the world's most
NOTE: Clearances may only be reduced by means
approved by the regulatory authority having jurisdiction
B. Sample of Serial Number / Safety Label
LOCATION: Back of unit
CAUTION
ATTENTION:
APPAREIL DE CHAUFFAGE DE PIÈCE, DE TYPE DE
LISTED ROOM HEATER, SOLID FUEL TYPE.
COMBUSTIBLE SOLIDE, PAS APPROUVÉ POUR
ALSO FOR USE IN MOBILE HOMES USA ONLY.
MOBILE HOME INSTALLATIONS AU CANADA"Pour
(UM) 84 HUD . "For Use with Solid Wood Fuel
Usage Avec Bois Solide Seulement"
Only"
PRÉVENTION DES FEUX DE MAISON
PREVENT HOUSE FIRES
Installez et utilisez en accord avec les instructions
Install
and
use
only
in
accordance
with
d'installation et d'opération du fabricant. Contactez le bureau
manufacturer's
installation
and
operating
de la construction ou le bureau des incendies au sujet des
instructions. Contact local building or fire officials
restrictions et des inspections d'installation dans votre
about restrictions and installation inspections in
voisinage. Ne pas obstruez l'espace en dessous de l'appareil.
your area. Do not obstruct the space beneath
heater.
PAS APPROUVÉ POUR MOBILE HOME INSTALLATIONS
WARNING - For Mobile Homes: Do not install in
AU CANADA!
a sleeping room. An outside combustion air inlet
Référez vous aux instructions du fabricant et des codes
must be provided and unrestricted while unit is in
locaux pour les précautions requises pour passer une
use. The structural integrity of the mobile home
cheminée à travers un mur ou un plafond combustibles, et les
floor, ceiling and walls must be maintained. The
compensations maximums. Inspectez et nettoyez la
stove needs to be properly grounded to the frame
cheminée fréquemment. Sous certaines conditions, il se peut
of the mobile home.
Components required for
que la créosote s'accumule rapidement.
mobile home installation:
Outside Air Kit, Part
Ne pas connecter cet appareil à une cheminée servant un
Number OAK-ACC. Refer to manufacturer's
autre appareil. Composants Optionnels: Ventilateur Optionnel,
instructions and local codes for precautions
Pièce BK-ACC. Puissance Électrique: 115 VAC, 1.2 Amps, 60
required
for
passing
chimney
through
a
Hz. Éloignez le fil électrique de l'appareil. Ne pas faire passer
combustible wall or ceiling and maximum offsets.
le fil électrique au dessus ou en dessous de l'appareil.
Inspect and clean chimney frequently - Under
DANGER: Il y a risque de décharge électrique. Déconnectez
Certain Conditions of Use, Creosote Buildup May
le fil électrique de la prise de contact avant le service.
Occur Rapidly. Do not connect this unit to a
Remplacez la vitre seulement avec une vitre céramique de 5
chimney serving another appliance. Optional
mm disponible chez votre fournisseur. N'élevez pas le feu.
Components: Optional Blower, Part BK-ACC.
Bâtissez le feu de bois directement sur l'âtre. Ne pas
Electrical Rating:
115 VAC, 1.2 Amps, 60 Hz.
surchauffer. Si l'appareil de chauffage ou le tuyau de
Route power cord away from unit. Do not route
cheminée rougissent, vous surchauffez. Opérez l'appareil
cord under or in front of appliance.DANGER: Risk
seulement lorsque la porte de chargement est fermée.
of electrical shock.
Disconnect power supply
Ouvrez la porte seulement lorsque vous devez ajouter des
before servicing. Replace glass only with 5mm
combustibles dans le feu.
ceramic available from your dealer. Do not use
grate or elevate fire. Build wood fire directly on
hearth. Do not overfire - if heater or chimney
connector glows, you are overfiring. Operate only
with the fuel loading door closed. Open only to
add fuel to the fire.
FLOOR PROTECTION:
In the USA floor protector must be Type II with an R
Au Canada protecteur de plancher doit être de type II avec
value of 1.06 extending beneath heater and to
et la valeur de R de 1,06 étendant sous chauffage et à
front/sides/rear as indicated on the diagram.
l'avant / côtés / arrière, comme indiqué sur le schéma.
Exception: protections de plancher non combustibles
Exception: Non-combustible floor protections must
doivent s'étendre au-dessous du conduit de fumée lorsqu'il
extend beneath the flue pipe when installed with
est installé avec ventilation horizontale et étendre 2 pouces
horizontal venting and extend 2 inches (51mm)
(51 mm) de chaque côté.
beyond each side.
39-3/8
in.min.
Fuel loading door
8 in.
8 in.
16 in. from glass
35-3/8
in. min.
Owners Manual
1445 N. Highway, Colville, WA 99114
Made in U.S.A.
Fabriqué aux États-Unis-d'Amérique par des pièces d'origine américaine et pièces importées.
2
and Welcome to the Quadra-Fire Family
HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS.
:
KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS
CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER
DES BRÛLURES À LA PEAU. GARDEZ LES MEUBLES ET LES MATÉRIAUX COMBUSTIBLES LOIN DE L'ESPACE DÉSIGNÉ DE L'APPAREIL. VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS.
Tested and
O-T L
Listed by
C
US
OMNI-Test Laboratories, Inc.
Report:
061-S-87-2
SINGLE WALL: Six inch (6 inches) (152mm) diameter, minimum 24 MSG black or
blued steel connector pipe, with a listed factory-built UL103HT* Class "A" chimney,
suitable for use with solid fuels, or a masonry chimney, and the referenced clearances.
DOUBLE WALL: Six inch (6 inches) (152mm) diameter, listed double wall air
insulated connector pipe with listed factory-built UL103HT* Class "A" chimney, or a
masonry chimney and the referenced clearances
*In Canada must comply with Standard CAN/ULC-S629-M87 for the 650 degree
Factory-built chimneys.
MOBILE HOME (USA ONLY): Use double wall pipe by Dura-Vent DVL, Selkirk
Metalbestos DS or Security DL double wall connector pipe. Must be equipped with a
spark arrestor. Apply double wall clearances below when installing unit.
MINIMUM CLEARANCES TO COMBUSTIBLES In Inches & (Millimeters)
NOTE: All "A" , "C" and "F" Dimensions are to inside diameter of the flue collar.
INSTALLATION: FULL VERTICAL AND ALCOVE/ Verticale complète et d'une alcôve
SINGLE WALL PIPE
DOUBLE WALL PIPE
o
INSTALLATION: 90
ELBOW OFF TOP OF STOVE THROUGH BACKWALL
o
INSTALLATION: 90
DU COURBURE AU DESSUS DE HAUT DU POÊLE A TRAVERS LE MUR ARRIERE
DOUBLE WALL PIPE ONLY
INSTALLATION: HORIZONTAL THRU WALL
INSTALLATION: HORIZONTALE AU MUR
SINGLE WALL PIPE
PROTECTION DU PLANCHER:
INSTALLATION: ALCOVE - Six inch (6 inches) (152mm) diameter listed SINGLE WALL or DOUBLE WALL air insulated connector pipe with UL 103 HT listed factory-built Class "A" chimney, or a masonry
chimney. (Mobile Home must be equipped with a spark arrestor.) Maximum depth of Alcove shall be no more than 48 inches (1219mm) with a minimum height of 84 inches (2133mm) from floor to bottom
of ceiling, and the referenced clearances.
INSTALLATION: ALCÔVE -
De six (6 inches) (152mm) de diamètre, le connecteur du conduit d'air isolé pour du mur simple au mur double avec une cheminée bâtit en usine 103HT de Classe "A", ou une cheminée de briques. (Les
maisons mobiles doivent être équipées d'un arrêt d'étincelle). La profondeur maximum de l'alcôve ne doit pas être de plus de 48 inches (1219mm) avec une hauteur minimum de 84 inches (2133mm) la distance entre du plancher et
plafond inférieur, et des espaces libres alloués.
BACKWALL/SIDEWALL
203mm (8 in.)
MUR ARRIÈRE/MUR DE CÔTÉ
203mm
203mm
(8 in.)
(8 in.)
B
A
1254mm
(49-3/8
in.)
minimum
457mm (18 in.)
1114mm (43-7/8
in.)min.
Manufactured by:
Certified to comply with 2015 particulate emission standards at 2.0 g/hr EPA Methods 28 and 5G. Not approved for sale after May 15, 2020.
This wood heater needs periodic inspection and repair for proper operation. Consult the owner's manual for further information. It is against federal regulations
to operate this wood heater in a manner inconsistent with the operating instructions in the owner's manual.
2015
www.quadrafire.com
of US and imported parts.
advanced technology to achieve the optimum opera-
tion of our stoves, inserts and fi replaces. And yet we are
old-fashioned when it comes to craftsmanship. Each unit
is meticulously fabricated and gold and nickel surfaces are
hand-fi nished for lasting beauty and enjoyment. Our pledge
to quality is completed as each model undergoes a quality
control inspection.
We wish you and your family many years of enjoyment in the
warmth and comfort of your hearth appliance. Thank you for
choosing Quadra-Fire.
EXPLORER III
Portland
Oregon USA
WOOD STOVE
TESTED TO:/ TESTÉ À:
Conforms to UL Stds 1482-11 & 737-11
Certified to ULC Std S627-00
VENT SPECIFICATIONS:
MUR SIMPLE: De six (6 inches) (152mm) de diamètre le connecteur de conduit de
minimum d'acier noir ou bleu de minimum de 24MSG, avec une cheminée bâtit en
usine UL103HT* de Classe "A", adéquate pour usage avec les combustions solides,
ou une cheminée de briques, avec espaces libres référés.
MUR DOUBLE: De six (6 inches) (152mm) de diamètre, le connecteur du conduit
d'air isolé pour mur double avec une cheminée bâtit en usine UL103HT* de Classe
"A, ou une cheminée de briques, avec espaces libres alloués.
*Au Canada doit conformer a CAN/ULC-S629-M87 la norme pour 650 degré C cheminée
bâtit en usine.
MAISON MOBILE: PAS APPROUVÉ POUR MOBILE HOME INSTALLATIONS AU
CANADA
ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES En Pouces &
NOTE: Toutes les dimensions "A", "C", et "F" sont à partir du diamètre intérieur de
A
B
C
D
E
F
7.5 (191) 7.0 (178) 24.0 (610) 12.0 (305)
7.0 (178) 15.0 (381) 52.5 (1334)
6.5 (165) 6.0 (153) 24.0 (610) 12.0 (305)
5.0 (127) 13.0 (330) 52.5 (1334)
6.5 (165) 6.0 (153) 24.0 (610) 12.0 (305)
NA
NA
52.5 (1334) 27.0 (686)
NA
NA
37.5 (953) 25.5 (648)
NA
NA
52.5 (1334)
CORNER INSTALLATION
INSTALLATION DU COIN
H
G
C
F
B
D
E
U.S. ENVIRONMENTAL PROTECTION AGENCY
2016
2017
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE
7060-227D
!
SERIAL NO. / NUMÉRO DE SÉRIE
007063
room for .14 x .875" S/N
1.5" x .375 Barcode Label
SPÉCIFICATIONS DE LA VENTILATION:
(millimètres)
l'entrée du conduit.
G
H
I
J
NA
NA
NA
CONDUIT DU MUR SIMPLE
NA
NA
NA
CONDUIT DU MUR DOUBLE
NA
NA
CONDUIT DU MUR DOUBLE
NA
12.0 (305) 52.5 (1334)
CONDUIT DU MUR SIMPLE
HORIZONTAL THRU
90 OFF TOP UP &
WALL
OUT CEILING
CLEARANCE
HORIZONTALE AU
ESPACE LIBRE DU
MANTEL
MUR
12" MAX
DESSUS DE
L'APPAREIL
AU PLAFOND AVEC
J
90
DE COURBURE
I
Install Manual
OCT
NOV
DEC
Serial No.
Model
Name
Test Lab &
Report No.
Mfg. Date
February 25, 2016