Component Functions - Quadra-Fire Edge60 Owner's Manual

Zero clearance pellet fireplace nutural/curved/tuscan/studio
Table of Contents

Advertisement

R
R R
B. Component Functions
1. Auto-Clean Motor
Location: Behind and under the firepot on the left side, inside
the convection air chamber
Function: It automatically opens and closes the firepot floor
so ashes can fall into the ash pan.
2. Auto-Clean Switch
Location: On top of the auto-clean motor
Function: Communicates to the control board when the firepot
floor is open and when the auto-clean system has completed
its cycle and is back in the home (closed) position.
3. 12 Volt Battery Back-Up Cable (Optional Accessory)
Location: Plugs into the appliance at the lower left front of
the appliance.
Function: An icon will display on the wall control when the
appliance has lost main power and is running on battery
back-up.
4. Combustion (Exhaust) Blower
Location: Mounted in the bottom right rear of appliance.
Function: Pulls the exhaust from the appliance and pushs it
out through the venting system.
5. Control Board
Location: Lower left side of appliance.
Function: Controls the functioning of the appliance and
communicates with the wall control. The control board can
only be opened by an authorized dealer.
6. Convection Blower
Location: Mounted at the bottom left rear of the appliance
Function: Pushes heated air through the heat exchange
system into the room.
7. Door Switch
Location: Mounted on the right side of the firebox behind
the door handle
Function: Senses when the door is open and will display an
icon on the wall control and will turn off the auto-clean system
and feed motor for safety.
8. Feed System
Location: On the right side of the appliance and can be
removed as an entire assembly. The assembly includes
the feed motor, mounting bracket, bearing and feed spring
(auger).
Function: The hollow feed spring (auger) pulls pellets up the
feed tube from the hopper area and drops them down the
feed chute into the firepot
April 9, 2009
When describing the location of a component,
it is always AS YOU FACE THE FRONT OF
THE APPLIANCE.
9. Firepot
Location: Inside firebox and is made of high quality ductile
iron.
Function: The floor of the firepot automatically opens for
cleaning and is operated by the auto-clean firepot system.
The floor needs to return to a completely closed position or
the appliance will not operate properly.
10. Fuses
Location: One AC fuse and one DC fuse is located on
the inside of the control board and a third fuse is located
in the power supply. Figure 54.1 & 54.2 on page 54 re-
spectively.
Function: The AC fuse operates the igniter and the DC
fuse operates all of the other components. The third fuse
protects the components in the power supply. A fuse will
blow should a short occur and shut off power to the appli-
ance. The fuses can only be replaced by an authorized
dealer.
11. Heat Exchanger
Location: Behind the baffle. Remove the cast iron baffle
to access the heat exchanger.
Function: Transfers heat from the exhaust system into the
convection air chamber.
12. Hopper Lid Switch
Location: Outside of the hopper, front right side.
Function: Senses whether the hopper lid is open and dis-
plays an icon on the wall control and will turn off the feed
motor.
13. Interlock Switch
Location: Outside of the hopper, front right side.
Function: Causes the auger to stop functioning and will be
opened when the appliances slides are extended.
14. Igniter (Heating Element)
Location: Mounted on the base of the firepot.
Function: Combustion air travels over the red hot igniter
creating super heated air that ignites the pellets or other
fuels.
15. Power Receptacle
Location: Lower rear of the appliance
Function: Check the wall receptacle for 10 volt, 60 Hz
(standard current). Make sure the outlet is grounded and
has the correct polarity.
7051-158