EDGE 60 Pellet Fireplace
C. Frame the Fireplace
Figure 26.1 shows typical framing using combustible materials (x4 lumber shown).
•
Framing across the top of fireplace must be above top standoffs.
See page 33 for detailed information regarding sub-floor material requirements.
•
C
B
Figure 26.1 - Framing the Fireplace
Page 6
Header MUST NOT
be notched!
D = extra space needed
for securing fireplace to the floor
D
and for outside air connection if
A
it is installed on side of fireplace
See Section 8 for outside air locations.
Outside Air is REQUIRED for all installations.
inches
mm
*
If interior of chase will be drywalled, add the thick-
ness to this measurement.
** Adjust header height for a raised platform under
fireplace, Taking into consideration the maximum
height allowed for loading fuel into the hopper.
7051-158
A
B*
C**
7-1/
0
8-1/4
699
762
972
April 9, 2009
R
D
7
178