VT-UTF8 Combo Key Support
Sredir Memory Display Delay
Hardware Health Configuration
CPU Overheat Alarm
Fan Speed Control Modes
ACPI Configuration
ACPI Aware O/S
007-5759-001
Allows you to Enable or Disable VT-UTF8 combination key support for ANSI/VT100 terminals.
Use this setting to set the delay in seconds to display memory information.
Options are No Delay, 1 sec, 2 secs and 4 secs.
This setting allows you to specify the type of alarm for CPU overheating. Options include The
Early Alarm and The Default Alarm.
This feature allows the user to determine how the system will control the speed of the onboard
fans. The options are Full Speed/FS (Max Cooling), Performance/ PF (Better Cooling),
Balanced/BL (Balance between performance and energy saving), Energy Saving/ES (Lower
Power and Noise). Other items in the submenu are systems monitor displays for the following
information:
CPU 1 Temperature, CPU 2 Temperature, NB Temperature, VRD1 Temperature, VRD2
Temperature, System Temperature, Air Temperature, Fan 1 Reading, Fan 2 Reading, CPU1
Vcore, CPU2 Vcore, CPU1 Mem VTT, CPU2 Mem VTT, CPU1 Mem, CPU2 Mem, 1.1V, 1.8V,
5V +12V, 3.3 Vcc, 3.3 VSB, VBAT and HT Voltage.
This setting Enables or Disables ACPI support for the system's operating system. Options include
Yes (enabled) or No (disabled).
Advanced NorthBridge Chipset Control and Configuration
71