Level 1 Menu - Display Mode - Kaco Powador 2002 Operating Instructions Manual

Hide thumbs Also See for Powador 2002:
Table of Contents

Advertisement

S e ctio n 4 ·
O pera ti on
4.4
Level 1 menu – Display mode
The display menu is shown once the Powador inverter starts
up. Measured values and all of the counters are displayed
here. Key "1" is used to navigate through the individual menu
items.
Display of inverter type
Generator voltage and current
Line voltage, current and power
Daily peak capacity
Temperature inside unit
Counter yield
Yield today
Total yield
(Total) economy of CO
Counter oper. hours
Operating hours today
Total operating hours
Figure 4.4: Display mode menu
Page 8
2
Explanation of the individual menu items:
Inverter type display
Display of the inverter type
Powador 2002 / 3002 / 4202 / 5002 / 6002
Generator voltage and current
The current voltage and current of the solar generator that is
connected to the inverter.
Line voltage, current and power
The current line voltage, line current and the power that is
currently being fed into the grid.
Daily peak capacity
The peak power of the day in question that was fed into the
grid for a short time.
Temperature inside unit
Displays the current heat sink temperature in °C. The unit
switches off if it becomes too hot.
Counter yield
This counter totals all yields until it is reset again. The customer
can confi gure the time periods for this counter, e.g. as
a monthly counter. The counter can be cleared in the "Clear
yield" confi guration mode.
Yield today
The power that has been fed into the grid during the current
day.
Total yield
The power that has been fed into the grid since start-up of the
inverter. The initial value can be set in the confi guration
mode.
(Total) economy of CO
2
Shows the CO
savings of this PV system compared to the
2
German electricity mix. The CO
the total yield counter and can also be cleared with this
counter (1 kWh corresponds to 0.56 kg of CO
Counter oper. hours
This counter totals all yields until it is reset again. The customer
can confi gure the time periods for this counter, e.g. as
a monthly counter. It can be cleared in the "Clear yield"
confi guration mode.
Operating hours today
Today's hours of operation. As soon as the inverter is in
standby mode (i.e. when LED (1) lights up), the running time is
added up.
Total operating hours
The hours of operation since start-up of the inverter. As soon
as the inverter is in standby mode (i.e. when LED (1) lights up),
the running time is added up.
Operating Instructions Powador 2002 / 3002 / 4202 / 5002 / 6002_EN
savings are calculated from
2
savings).
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powador 5002Powador 6002Powador 3002Powador 4202

Table of Contents