Ope rati on
. Level 1 menu – Display mode
The display menu is shown once the blueplanet inverter starts
up. Measured values and all of the counters are displayed
here. Key "1" is used to navigate through the individual menu
items.
Display of inverter type
Generator voltage and current
Grid voltage, current and power
Daily peak capacity
Temperature inside unit
Counter yield
Yield today
Total yield
(Total) economy of CO
Counter oper. hours
Operating hours today
Total operating hours
Figure 4.4: Display mode menu
Page 
2
Explanation of the individual menu items:
Inverter type display
Inverter type blueplanet 1502xi/2502xi display
Generator voltage and current
The current voltage and current of the PV solar generator that
is connected to the inverter.
Grid voltage, current and power
The current line voltage, line current, and the power that is
currently being fed into the power grid.
Daily peak capacity
The respective day's peak power that was fed into the grid for
a short time.
Temperature inside unit
Displays the current heat sink temperature. If the unit becomes
too hot, the unit will reduct power output or switch off.
Counter yield
This counter totals all yields until it is reset. The customer can
configure the time periods for this counter, e.g. as a monthly
counter. The counter can be cleared in configuration mode
"Clear yield".
Yield today
The power that has been fed into the grid during the current
day. This value resets to zero each morning.
Total yield
The power that has been fed into the grid since installation
of the inverter. The initial value can be set in configuration
mode.
(Total) economy of CO
2
Shows the CO
savings of this PV installation compared to the
2
German electricity mix. The CO
total yield counter and can also be cleared with this counter.
Counter oper. hours
This counter totals all yields until it is reset again. The cus-
tomer can configure the time periods for this counter, e.g. as
a monthly counter. It can be cleared in configuration mode
"Clear yield".
Operating hours today
Today's hours of operation. As soon as the inverter is in stand-
by mode (i.e. when LED (1) lights up), the running time is added
up.
Total operating hours
The hours of operation since installation of the inverter. As
soon as the inverter is in stand-by mode (i.e. when LED (1)
lights up), the running time is added up.
Operating Instructions blueplanet 1502xi/2502xi
savings are calculated from the
2