Sec tio n 4 ·
Ope ra ti on
4.5
Level 2 menu – Confi guration mode
AC T I O N
To access the confi guration mode, press both keys at the
same time. The software version is displayed. Pressing
key "1" now switches to the next menu item. Changes
can be made in the respective menu item by pressing key
"2". The setting value increases each time key "2" is
pressed. If the maximum value has been reached, the
value returns to the minimum setting option.
Software version
Serial number
Current country
Language selection
Clear the grid feed counter
Defi ne total yield? (yes/no)
Defi ne total yield, if (yes) was previously selected
Select interface (RS232/RS485)
Settings for the RS485 address
S0 interface
Quick start
Figure 4.5: Confi guration mode menu
Operating Instructions Powador 2002 / 3002 / 4202 / 5002 / 6002_EN
Explanation of the individual menu items:
Software version
The current software version is displayed here.
Serial number
Display of the serial number specifi c to the unit.
Current country
Display of the current country settings.
Language selection
The language of the confi guration interface can be selected
here.
Clear the grid feed counter
When the grid feed counter is cleared, all counters ("Counter
yield" and "Counter oper. hours") are reset to zero.
To clear the counters, select "Yes" with key "2", and confi rm
your selection by pressing the "1" key. The required code is
"2", and is entered using key "2". After confi rming again with
key "1", all counters are cleared. "Grid feed counter cleared!"
is shown to confi rm that the counters have been cleared.
"Counter yield" and "Counter oper. hours" can be cleared sepa-
rately from the other counters. These counters are cleared in the
confi guration menu using key "2" and the code "2". "Counter
yield" and "Counter oper. hours" are always cleared together.
Defi ne total yield
Choose whether the total yield should be defi ned (yes/no).
Defi ne total yield
Specify the counter reading for the total yield so that the
counter does not begin at zero after start-up.
Choice of interface and address setting
Using the "Select interface" menu item, you can use key "2"
to switch between the RS232 and RS485 interfaces.
If the RS485 interface is activated, you can reach the address
setting by pressing key "1". By pressing key "2", the address
can be set in a consecutive manner from 1 to 32.
The address then jumps back to 1. The RS485 interface is used
to communicate with the Powador-proLOG. If several inverters
are connected to a Powador-proLOG, each address may only
be used once. Because of this, it is possible to monitor 32
Powador inverters with one Powador-proLOG.
To connect the RS485 interface, please contact your installer.
S0 interface pulse rate
The S0 interface is designed as a galvanically isolated
transistor output. This interface is designed according to
"DIN 43864 – Current interface for transmitting pulses from
a pulsing counter to a tariff metering unit".
The S0 interface pulse rate can be chosen in three unit inter-
vals: 500, 1,000 and 2,000 pulses/kWh.
To connect the S0 interface, please contact your installer.