RAM Storage: The scanner will not power down while it contains data that
has not been transmitted to the base, even if it reaches a power down time-
out. However, if the scanner runs out of battery power, it will power down
and the data will be lost.
Default = Flash Storage.
* Flash Storage
RAM Storage

Batch Mode Quantity

When in Batch Mode, you may wish to transmit the number of multiple bar
codes scanned, rather than a single bar code multiple times. For example,
if you scan three bar codes called XYZ with Batch Mode Quantity Off,
when you transmit your data it will appear as XYZ three times. Using
Batch Mode Quantity On and the Quantity Codes
(page
3-17), you could
ouptut your data as "XYZ, 00003" instead. Default = Batch Mode Quantity
Off.
* Batch Mode Quantity Off
Batch Mode Quantity On
Entering Quantities
Quantity Codes
(page
3-17) allow you to enter a quantity for the last item
scanned, up to 9999 (default = 1). Quantity digits are shifted from right to
left, so if a 5th digit is scanned, the 1st digit scanned is discarded and the
2nd, 3rd and 4th digits are moved to the left to accommodate the new digit.
For example, if the Quantity 5 bar code is scanned after the quantity has
been set to 1234, then the 1 is dropped, the quantity will be 2345.
Example: Add a quantity of 5 for the last item scanned.
1. Scan the item's bar code.
2. Scan the quantity 5 bar code.
Example: Add a quantity of 1,500 for the last item scanned.
1. Scan the item's bar code.