last set of barcode data is retransmitted and the scanner waits for ACK/NAK again.
Turn On the ACK/NAK protocol by scanning the ACK/NAK On barcode below. To
turn Off the protocol, scan ACK/NAK Off. Default = ACK/NAK Off.
ACK/NAK On
Scanner to Bioptic Communication
The following settings are used to set up communication between Honeywell
scanners and bioptic scanners.
Note: The scanner's baud rate must be set to 38400 and the RS232 timeout must be set to
3000 in order to communicate with a bioptic scanner. See
25 and
Scanner-Bioptic Packet Mode
Packet Mode On must be scanned to set the scanner's format so it is compatible
with a bioptic scanner. Default = Packet Mode Off.
* Packet Mode Off
Scanner-Bioptic ACK/NAK Mode
Bioptic ACK/NAK On must be scanned so the scanner will wait for an ACK or NAK
from a bioptic scanner after each packet is sent. The Scanner-Bioptic ACK/NAK
Timeout (below) controls how long the scanner will wait for a response. Default =
Bioptic ACK/NAK Off.
* Bioptic ACK/NAK Off
30
RS232 Timeout
on page 29 for further information.
* ACK/NAK Off
RS232 Modifiers
Packet Mode On
Vuquest 3320g User Guide
on page