Environment; Power Specification; Input Power Requirements - HP TC4100 Operation And Maintenance Manual

Tower server
Hide thumbs Also See for TC4100:
Table of Contents

Advertisement

Chapter 9

Environment

The specifications listed below can vary if you install a mass storage device in your HP Server tc4100 that has
more stringent environmental limits. Ensure that the operating environment is suitable for all mass storage
devices in use.
Table 9-5. Environmental Requirements
BTU
Temperature
Humidity
Altitude
Acoustic Emissions

Power Specification

Input Power Requirements

Table 9-6
displays the HP Server tc4100 input power requirements.
Table 9-6. Input Power Requirements
Input Voltage and Frequency
Maximum Inrush Current
Delayed Action Circuit Breaker
Recommended
NOTE
Some local codes allow 16-amp service for a 16-amp device. Consult a qualified
electrician or local regulatory authority before beginning electrical site preparation.
1845 BTU/hr maximum
Operating 5° C to 35°C
(41°F to 95° F)
Non-operating –40° C to +65° C
(–40° F to +149° F)
Operating 20% to 80% relative humidity
(non-condensing)
Non-operating 5% to 95% relative humidity
(non-condensing)
Operating -30 to 3,045 m (10,000 ft)
Non-operating -30 to 12,180 m (40,000 ft)
Sound Level: (LpA) < 43 dB(A) bystander position
100-240 ±10%; 50/60 Hz
8 AMPs peak (for 1 power supply) 120 VAC or
16 AMPs peak (for 2 power supplies)
16 AMPs peak (for 1 power supply) 240 VAC or
32 AMPs peak (for 2 power supplies)
North America: a 20 A minimum delayed action
circuit recommended for each 16 A power
distribution unit (PDU) that is connected to an HP
Server tc4100.
Europe (single server in a rack): a 16 A minimum
circuit with one IEC-MCB C-type breaker for
each 16 Amp PDU.
Europe (single server in a rack): a 16 A minimum
circuit with one IEC-MCB D-type breaker for
each 16 Amp PDU.
Specifications
124