Wedge Quiet Interval

This option specifies the amount of time to look for keyboard activity before the read-
er breaks the keyboard connection in order to transmit data to host. The selectable
range for this feature is from 0 to 990ms in 10ms increments.
Follow these instructions to set this feature:
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with lead-
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
4. Scan the barcode: SELECT WEDGE QUIET INTERVAL SETTING.
5. Scan the appropriate two digits from the keypad in
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
This completes the procedure to set the Wedge Quiet Interval. See
examples of how to set this feature.
Table 14. Timeout Setting Examples
STEP
ACTION
1
Desired Setting
Divide by 10 (and pad with leading
2
zeroes)
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT WEDGE QUIET INTERVAL SETTING
Scan Two Characters From
5
Appendix E, Keypad
6
Scan ENTER/EXIT PROGRAMMING MODE
Product Reference Guide
This feature applies ONLY to the Keyboard Wedge interface.
NOTE
ing zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
Mode.
the duration which was determined in the steps above. You will hear a two-beep indica-
tion after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.
NOTE
Mode.
10ms
01
'0' and '1'
Appendix E,
EXAMPLES
150ms
600ms
15
60
'1' and '5'
'6' and '0'
Wedge Quiet Interval
Keypad, that represent
for some
Table 14
850ms
85
'8' and '5'
73