Codabar — cont.

Codabar Set Length 1

This feature specifies one of the barcode lengths for
is the minimum label length if in
Fixed Length
The length must include at least one data character.
The length can be set from 3 to 50 characters.
Follow these instructions to set this feature:
1. Determine the desired character length (from 3 to 50). Pad the number with leading
2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
3. Scan the barcode: SELECT CODABAR LENGTH 1 SETTING.
4. Scan the appropriate two digits from the keypad in
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
This completes the procedure. See
Table 29. Codabar Length 1 Setting Examples
STEP
ACTION
Desired Setting (and pad with
1
leading zeroes)
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT CODABAR LENGTH 1 SETTING
Scan Two Characters From
4
Appendix E, Keypad
5
Scan ENTER/EXIT PROGRAMMING MODE
Product Reference Guide
Mode. Length includes the barcode's start, stop, check and data characters.
zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
Mode.
the length setting which was determined in the steps above. You will hear a two-beep indi-
cation after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.
NOTE
Mode.
03 Characters
'0' and '3'
Codabar Length Control
Mode, or the first fixed length if in
Variable Length
Appendix E,
for some examples of how to set this feature.
Table 29
EXAMPLES
09 Characters
15 Characters
'0' and '9'
'1' and '5'
Codabar
. Length 1
Keypad, that represent
50 Characters
'5' AND '0'
223