Toshiba Strata IPT User Manual page 114

Lcd featurephones
Hide thumbs Also See for Strata IPT:
Table of Contents

Advertisement

LCNU-C1A/LCNU-D1A/
LCNU-E1A
TNV3
LPFU1A
Any peripheral apparatus connected to the above ports must have the same EN60950 classification. ie.
-SELV ports must only be connected to SELV type ports.
-TNV ports must only be connected to TNV type ports.
1.3. The Strata CIX Office system must be hardwired into a switched fused spur, (which should comply with
the requirements of a disconnecting device as specified in the standard EN60950), the switch on the fused
spur outlet shall be considered the AC power disconnection device. This spur must be installed in
accordance with 16th edition of the IEE wiring regulations, aka BS7671:1992 or the latest edition of this
standard.
1.4. Environmental Installation details.
The Strata CIX Office is designed to work within the following environmental conditions:
-Operating temperature 0
-Humidity 20% to 80%
2.
EMC Compliance.
Toshiba Information Systems (U.K.) Ltd declares that the Strata CIX Office complies with the EEC's EMC
directive, Directive No. 89/366/EEC as amended by directive 92/31/EEC. The product has been assessed
and found to comply with the following product specific standards:
EN55022:1998-9, EN/IEC61000-3-2/1995, EN/IEC61000-3-3/1995 (Emissions)
EN52024:1998, EN61000-4-2/1995+A1:1998, EN61000-4-3/1997+A1:1998, EN61000-4-
4/1995+A1:2001, EN61000-4-5/1995+A1:2001, EN61000-4-6/1995+A1:2001, (Immunity)
The notes listed below form part of the products' compliance with the aforementioned European Norm.
To ensure EMC compliance the system must installed in accordance with the instructions in the
"Installation and Maintenance" manual. In order to maintain compliance any shielded cables supplied
and/or ferrite suppression cores must be used.
Equipment details Strata CIX
Base Cabinet Dimensions-
Height
89mm
Width
483mm(with ears)
440mm (without ears)
Depth
410mm
Weight
7.2 kg (Cabinet & PSU only)
WARNING:
This is a Class A product. In a domestic environment this Product may cause radio interference in
which case the User may be required to take adequate measures.
3.
Type Approval Declaration.
Toshiba Information Systems (UK), Ltd, (TIU), hereby declares that the Strata CIX Office product complies
with the requirements of the EC Directive 1999/5/EC, (aka Radio & Telecommunications Terminal
Equipment Directive). A manufacture's Declaration under this Directive allows connection to the relevant
Public Network Services and the right to place the Product on the market.
STRATA IPT/DKT FEATUREPHONE USER GUIDE
BSTU1A, RSTU3A, BWDKU1A, RCOU3A, RGLU3A,
RDDU2A, RBSU1A, RBUU1A, REMU2A, RCIU2A
8-port Power Failure Transfer Unit for RSTU1A,
RSTU3A, RCOU3A
o
o
C to 40
C
Expansion Cabinet Dimensions-
Height 89mm
Width 483mm(with ears)
440mm (without ears)
Depth 410mm
Weight 7.0 kg (Cabinet & PSU only)
Toshiba Business Communications Division
114 of 124