Duct Cover; Installation Information - GE ZV800SJSS Technical Service Manual

36-in. chimney vent hood
Hide thumbs Also See for ZV800SJSS:
Table of Contents

Advertisement

Installation Information

The vent hood is heavy. Adequate structural support
should be provided in all types of installations. The
hood should be secured to vertical studs in the wall,
or to a horizontal support.
Hood Dimension and Clearance
* Height to
Ceiling
1-1/2"
12-15/16" at Sides,
*The Supplied Duct Cover fits
13-11/16" at Center
8 ft. to 10 ft. Ceiling Heights.
The vent hood should be installed 24-in. min.
and 30-in. max. above the cooking surface. The
telescopic duct cover conceals the duct work
running from the top of the hood to the ceiling.
The duct cover is sized to reach 8- to 10-ft. ceiling
heights. The hood installation height, from the
cooking surface to the bottom of the hood, depends
upon ceiling height.
Wall Mounted Installations
The chimney vent hood may be installed on a wall
and vented to the outdoors or recirculated indoors.
Both venting options can be accomplished in a wall
mounted installation.
24" Min.
30" Max.
Note: The vent hood
canopy extends
forward 5-7/8".
35-7/8"
Under-Cabinet Installations
The hood may be installed beneath a cabinet.
The cabinet must measure at least 20-in. from
the bottom frame to the inside top. Both venting
options can be accomplished in an under-cabinet
installation. (Custom cabinet modifi cation is required
for recirculating operation.)
*25-1/2" Recommende d
*Depending on Cabinet Height
Note: Installation and removal of the hood will
require removal of the cabinet as specifi ed in the
installation manual.

Duct Cover

Telescopic duct covers conceal the duct work,
running to the ceiling. The upper duct section may
be mounted in one of two ways depending on how
the chimney hood is vented. If it is vented to the
outside, the upper section will be attached to a duct
bracket mounted to the ceiling and the duct cover
will be installed with the vent holes at the bottom.
If the chimney vent hood is set up to recirculate the
air indoors, the upper section will be attached to an
air defl ector mounted to the wall and the duct cover
will be installed with the vent holes at the top.
Vented to the Outside
Mounting
Screws
Vent Holes
– 7 –
*24"
Indoor Recirculation
Mounting
Screws
Vent Holes