Light Receptacles - GE ZV800SJSS Technical Service Manual

36-in. chimney vent hood
Hide thumbs Also See for ZV800SJSS:
Table of Contents

Advertisement

Light Receptacles

The 2 light receptacles are recessed in the light
shield and are located on the underside of the
canopy. Each receptacle consists of a bulb, socket,
and glass cover.
WARNING: Before replacing a receptacle,
disconnect electrical power to the hood at the main
fuse or circuit breaker panel. DO NOT touch a hot
receptacle with bare hands or a damp cloth. The
glass cover and lightbulb should be allowed to cool
completely.
To remove a light receptacle:
1. Remove visor. (See
Visor.
2. Remove two Phillips-head screws from the rear
of the light shield.
Bottom View
)
– 13 –
3. Lower the light shield and slide it toward the
rear to clear the front tabs.
4. Disconnect the light receptacles on each side of
the light shield.
Disconnect
5. Depress the receptacle retaining clips. Remove
the receptacle from the light shield.
Disconnect

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zv800bjbb

Table of Contents