Technical Data - GE ZV800SJSS Technical Service Manual

36-in. chimney vent hood
Hide thumbs Also See for ZV800SJSS:
Table of Contents

Advertisement

ZV800SJSS, ZV800BJBB
Electrical Specifi cations
This information is intended for use by persons possessing adequate backgrounds of electrical, electronic
and mechanical experience. Any attempt to repair a major appliance may result in personal injury
and property damage. The manufacturer or seller cannot be responsible for the interpretation of this
information, nor can it assume any liability in connection with its use.
WARNING: Disconnect power before servicing!
IMPORTANT: Disconnect ALL grounding devices.
All parts of this appliance capable of conducting electrical current are grounded. If grounding wires, screws,
straps, clips, nuts or washers used to complete a path to ground are removed for service, they must be
returned to their original position and properly fastened.
GROUNDING SPECIFICATIONS:
Ground Path Resistance
Insulation Resistance
INSTALLATION REQUIREMENTS:
Electrical Supply - The hood must be connected to an individual, properly grounded branch circuit of 120
V, 60 Hz., and protected by a 15- or 20-amp circuit breaker or time delay fuse. Wiring must be 2- wire with
ground. Wire size must conform to the National Electrical Code or the prevailing local code. Refer to the
rating plate located on the left side, visible when fi lters are removed.
WARNING: Improper connection of aluminum house wiring to copper leads can result in a serious problem.
Use only connectors designed for joining copper to aluminum, and follow the manufacturer's recommended
procedure closely.

Technical Data

0.10 Ω Max.
250 Ω Min.
– 6 –