Insure that the distance from the spindle to the pivot point of the tonearm is exactly 222
mm. Moving the armboard in one direction or another will allow you to locate the correct
position. Once located, tighten the armboard down. Shown in the picture below. You can
also use the optional clearaudio cartridge alignment gauge.
For the exact adjustemts should be the cartridge mounted!
Pic. 18: Mounting the clearaudio Satisfy tonearm
VTA adjustments are accomplished by loosening the two lock screws an the side of the
armboard base (shown in picture 1 and 2). Once loose, you can moove the arm up or
down to achieve the desired VTA. Tighten both screws when finished. Re-check tracking
force after adjusting VTA.
1
2
Pic. 19: VTA adjustment