Chapter 2
Installation Overview
Figure 2-5
1

Installation Summary

During the installation of the bridge, you will perform the following operations:
Tip
Note
Tip
Note
OL-4072-04
Grounding Block
1
1
F-type coaxial connectors
Connect a user-supplied Category 5 Ethernet cable from your wired LAN network to the power
injector.
Connect the dual-coax Ethernet cables between the power injector and the grounding block.
You can connect the dual-coax cable connectors to either of the grounding block connectors or
the power injector's dual-coax ports. The bridge senses the Ethernet signals and automatically
switches internal circuitry to match the cable connections.
You should securely tighten the cable connectors (15 to 20 inch-pounds) using a small wrench.
Connect a ground wire to the grounding block.
Mount the bridge to the external tower or mast. For additional information, refer to the Cisco Aironet
1400 Series Wireless Bridge Mounting Instructions that shipped with your bridge.
Connect a ground wire to the bridge (use the bridge ground lug).
Connect the dual-coax Ethernet cables to the grounding block and to the bridge.
You can connect the dual-coax cable connectors to either of the grounding block connectors or
the bridge's dual-coax ports. The bridge senses the Ethernet signals and automatically switches
internal circuitry to match the cable connections.
You should securely tighten the cable connectors (15 to 20 inch-pounds) using a small wrench.
Connect the AC power cord to the 48-VDC power module.
Cisco Aironet 1400 Series Wireless Bridge Hardware Installation Guide. OL-4072-03
2
2
Ground wire lug

Installation Summary