Checking Power - Cisco Aironet 1400 Series Hardware Installation Manual

Hide thumbs Also See for Aironet 1400 Series:
Table of Contents

Advertisement

Checking Power

Table 6-3
Uplink Activity
Blinking Green
Amber
Amber
Off
Red
Checking Power
You can verify the availability of power to the bridge by checking the power injector LEDs (see
Figure
Cisco Aironet 1400 Series Wireless Bridge Hardware Installation Guide. OL-4072-03
6-6
Power Injector LED Indications (continued)
Injector Status
Green
Blinking Green
Blinking Amber —–
Amber
Amber
Red
Red
6-2):
Power LED
Green color indicates 48 VDC is available to the power injector (see
Off indicates 48 VDC is not available to the power injector—verify that the power module is
connected to the power injector and to an AC receptacle and that AC power is available.
Uplink Activity LED
Green or blinking green color indicates the bridge is operating.
Ethernet Activity Description
Transmitting and receiving Ethernet packets
between the power injector and the bridge.
Power injector internal memory
error—disconnect and reconnect the power
injector power plug. If the problem continues,
contact technical support for assistance.
Bridge successfully passed Power On Self Test
(POST) and loaded the IOS image.
Bridge power is active and the bridge is loading
IOS image or POST operation has started.
Bridge has not been detected and bridge power
is not active. This might be caused by bad
connections or a defective cable or connector.
Verify that the dual-coax cables are connected
correctly to the power injector, grounding
block, and bridge. If the cables are connected
correctly, contact technical support for
assistance.
Amber
Power injector internal memory
error—disconnect and reconnect the power
injector power plug. If the problem continues,
contact technical support for assistance.
Off
Bridge is resetting the configuration to defaults;
mode button has been depressed more than 2
seconds but less than 20 seconds.
Image recovery mode, downloading new image;
mode button pressed more than 20 seconds.
Red
Power injector internal memory
error—disconnect and reconnect the power
injector power plug. If the problem continues,
contact technical support for assistance.
Chapter 6
Troubleshooting
Figure