Figure 171
Mini-touch panel circuit card
and connectors
Black/White LCD Mini-Touch Panels
Place the bottom panel on the mini-touch panel and align the mini-XLR
11.
mounting plate and screw holes. Insert the four Phillips-head screws and
tighten.
Plug the AXlink mini-XLR connector back into the mini-touch panel.
12.
AXU-MLC (/PB) and AXM-MLC (/PB)
Replace the batteries in the AXU-MLC (/PB) and AXM-MLC (/PB):
Discharge the static electricity from your body by touching a grounded object.
1.
Insert a flat-blade tool into the release slot on the mini-touch panel' s bezel and
2.
remove the engraved overlay.
Remove the four #6-32 mounting screws and carefully lean the mini-touch panel
3.
backward to expose the AXlink and RS-232 (optional) wiring.
Disconnect the AXlink and RS-232 4-pin header and remove the mini-touch
4.
panel from the back box or equipment rack.
Flip the mini-touch panel facedown onto a soft cloth and remove the touch
5.
overlay's ribbon cable connector and backlight connector from the circuit card.
Do not remove the cable on the battery-side of the circuit card. Figure 171 shows
the connectors on the circuit card.
Touch overlay
ribbon cable
Connector side of circuit card
4-pin AXlink connector
4-pin header connector
Backlight
connector
Replacing the Lithium Batteries
119