Flash Messages - Cisco Catalyst 4500 Series Message Manual

Cisco ios system message guide
Hide thumbs Also See for Catalyst 4500 Series:
Table of Contents

Advertisement

Chapter 2
Messages and Recovery Procedures
Error Message EC-5-NOPAGP:Invalid EC mode
Error Message EC-5-PORTDOWN: Shutting down [char] as its port-channel is admin-down
Error Message EC-5-STAYDOWN: [char] will remain down as its port-channel
admin-down
Error Message EC-5-UNBUNDLE:Interface [char] left the port-channel [char]
Error Message EC-5-UNSUITABLE:[char] will not join any port-channel

FLASH Messages

This section contains the Flash memory (C4K_FLASH) messages.
Error Message C4K_FLASH-4-COMPACTFLASHNOTFOUND: Cannot find compact flash
OL-11541-01
PAgP is not included in the image, so the EtherChannel mode cannot be set to
Explanation
desirable/auto.
Obtain an image that includes PAgP, or set the mode to ON.
Recommended Action
The administrative state of the aggregate port is down, which forces the administrative
Explanation
state of the port to also be down. The administrative state of the port is controlled by the
administrative state of its aggregate port.
Enter the no shutdown command on the aggregate port to activate the
Recommended Action
aggregation port.
An interface with EtherChannel configuration cannot be administratively up if its port
Explanation
channel is administratively down. Although this interface has an EtherChannel configuration, it has
no information about the port channel. The no shutdown command is not supported.
Wait for the module to come online.
Recommended Action
The interface fell off the bundle.
Explanation
This is an informational message only. No action is required.
Recommended Action
The configurations for PortFast, VMPS, and Dest-SPAN are incompatible with
Explanation
EtherChannel.
Unconfigure the three features so that the port can form a bundle.
Recommended Action
You may see this message if the compact flash is not inserted properly or if it is removed
Explanation
while the switch is trying to access the flash.
Recommended Action
Reinsert the compact flash and retry the operation.
Catalyst 4500 Series Switch Cisco IOS System Message Guide Release 12.2(31)SGA
FLASH Messages
[char] is
2-33

Hide quick links:

Advertisement

Table of Contents
loading